System Settings
ZFX-C User’s Manual
5
ADDITIONAL
FUNCTIONS
141
Output Conditions
When "Serial output" or "SD card" is output as the data output destination, set the output form and output
format.
ASCII format
When outputting measurement values in ASCII format, set the following items.
X
MENU mode - [System] - [Output] - [Date format (Serial)/(SD Card)]
Output format
Setup Item
Description
Output form
Selects ASCII.
Digits of integer
Sets the number of output digits of the integer section. When "0" is selected, all of the dig-
its of the data are output shifted to the left.
When there are fewer data digits than the preset number of digits, "0" is inserted in free
digits.
When there are more data digits than the preset number of digits, "9" is output for the pre-
set number of digits.
Range: 0 to 8 (default value: 8)
Digits of decimal
Sets the number of output digits past the decimal point. When "0" is selected, digits past
the decimal point are rounded up to the nearest integer.
Range: 0 to 3 (default value: 3)
Field separator
Sets the separator between individual output data items.
Range: None, Comma (default value), Tab, Space, Semicolon
Decimal separator
Sets the number of digits past the decimal point.
Range: None, Period (default value), Comma
Record separator
Sets the separator between individual output data records.
Range: None, Comma, Tab, Space, Delimiter (default value)
Display at time
Prefixes the output data with time information.
Range: OFF (default value), ON
File name
Sets the name of the output file. (only when SD card is selected) The directory "OUTFILE"
is automatically created in the root directory of the SD card. Output files are stored in this
directory.
When Display at time is set to "ON", the data is prefixed with the time information.
Note
<
Measurement
v
a
l
ue
o
f d
ata
0 >,
Fi
e
ld
separator
Re
c
or
d
separator
<
Measurement
v
a
l
ue
o
f d
ata
1>... <
Measurement
v
a
l
ue
o
f d
ata
31 >
De
li
m
i
ter
<
Year/month/
d
ay
>,
<
Hours/minutes/se
c
on
d
s
>,
<
Measurement
v
alue o
f
d
ata
0>,
<
Measurement
v
alue o
f
d
ata
1>
...
<
Measurement
v
alue o
f
d
ata
31>
Delimiter
Example:
On August
1
st
,
2
00
7
→
2
00
7/8/
1
Example:
At
1
minute
,
2
0
se
c
on
d
s past
1
2 am
→
1
2:
01
:2
0
Содержание Smart Sensor ZFX-C
Страница 2: ......
Страница 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Страница 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Страница 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Страница 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Страница 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...
Страница 227: ...INDEX 224 ZFX C User s Manual MEMO ...