6-3 Transferring Data from the CX-Designer
6-12
3. Select the
NS-Runtime
from the Comms. Method
4. Click the
OK
Button
to close the Comms. Method Dialog Box.
5. Transfer the project data by any of the following methods.
-
PT
Menu –
Transfer
–
Quick Transfer [To PT]
Menu
(Use this method to send only changed data to NS-Runtime.)
-
PT
Menu –
Transfer
–
Transfer [To PT]
Menu
(Use this method to send all project data to NS-Runtime.)
-
PT
Menu –
Transfer
–
Transfer [From PT] Menu
(Use this method to receive project data from NS-Runtime.)
-
PT
Menu –
Transfer
–
Transfer Program
–
Screen data transfer program
6. After the transfer, restart the NS-Runtime.
N
N
N
o
o
o
t
t
t
e
e
e
Project data cannot be transferred while NS-Runtime is running.
The downloaded project data will be stored in the following project storage folder.
\ NS-Runtime Installation folder \ Runtime
Project data that is stored in this folder can be directly opened from the CX-Designer.
In this case, it is not necessary to transfer the modified project data again.
Downloaded project data (Project data stored in \ NS-Runtime Installation folder
\ Runtime) cannot be transferred by the CX-Designer if the project data is being edited
with another CX-Designer.
Operation methods for using CX-Designer’s Menus and screen data transfer program
are the same as those for NS Series. For details, refer to the Transferring Data to the PT
in the CX-Designer Online Help.
Содержание NS-RUNTIME - SOFTWARE
Страница 1: ...NS Runtime Software USER S MANUAL Cat No V093 E1 04...
Страница 2: ......
Страница 28: ...1 4 Comparison between the NS Series and the NS Runtime 1 14...
Страница 38: ...2 6 User Interface 2 10...
Страница 56: ...3 5 Converting Projects 3 18...
Страница 84: ...4 5 Macros 4 28...
Страница 136: ...5 11 Window Size 5 52...
Страница 154: ...7 3 Error Messages and Countermeasures 7 6...
Страница 156: ......
Страница 157: ......