3 Functions of NB-Designer
3-90
NB-series Programmable Terminals NB-Designer Operation Manual(V106)
*Indirect Reference:
Refers to the variables that can be used by the setting or the upper/lower limit etc.
For example:
(a) When Setting Mode is “Set Value”.
Assuming the write address of the Command Button component is LW0 with the “Type” of “Set Value”,
check [Indirect Reference] and select “LW10” as the address of variable parameter.
When LW10 is 5, it means the Set Value is 5. In this case, clicking “Set” will write the value of LW10
(i.e. 5) into LW0.
JOG++
Everytime command button is pressed for the time longer than the time to be specified
“Delay Time”, the value * set to “Addend” is added to the value of the write address with the
interval set to “JOG Speed”.
The result will not exceed the “Upper”. When [Ignore Delay Time] is checked, the “Addend”
will be added to the value of the specified word address immediately each time the
component is pressed. If this component is pressed for a long time, the “Addend” will be
added to the value of the specified word address at the interval of “JOG Speed” time until
the “Upper” is reached.
JOG--
Everytime command button is pressed for the time longer than the time to be specified
“Delay Time”, the value set to “Subtrahend” * is subtracted from the value of the write
address with the interval set to “JOG Speed”.
The result will not be less than the “Lower”. When [Ignore Delay Time] is checked, the
“Subtrahend” will be added to the value of the specified word address immediately each
time the component is pressed. If this component is pressed for a long time, the
“Subtrahend” will be added to the value of the specified word address at the interval of
“JOG Speed” time until the “Lower” is reached.
JOG++ (Circle)
Everytime command button is pressed for the time longer than the time to be specified
“Delay Time”, the value * set to “Addend” is added to the value of the write address with the
interval set to “JOG Speed”.
Until the “Upper” is reached, and then it will increase from the “Lower” again.
JOG--(Circle)
Everytime command button is pressed for the time longer than the time to be specified
“Delay Time”, the value * set to “Subtrahend” is subtracted from the value of the write
address with the interval set to “JOG Speed”.
Until the “Lower” is reached, and then it will decrease from the “Upper” again.
Type
Descriptions
Содержание NB10W-TW01B
Страница 4: ......
Страница 10: ...Terminology 6 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Страница 448: ...3 Functions of NB Designer 3 406 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Страница 450: ...3 Functions of NB Designer 3 408 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Страница 462: ...4 Functions of NBManager 4 10 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Страница 472: ...4 Functions of NBManager 4 20 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Страница 482: ...5 Maintenance and Abnormality Handling 5 10 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Страница 528: ...8 Web Interface 8 10 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Страница 544: ...Appendices A 16 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Страница 546: ...Revision 2 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Страница 547: ......