Three-phase Phase-sequence Phase-loss Relay

 K8AB-PM

J-35

Mo

nit

o

ring

 

p

rod

ucts

Three-phase Phase-sequence Phase-loss Relay

K8AB-PM

Ideal for monitoring 3-phase power supplies 
for industrial facilities and equipment.

• Monitor overvoltages, undervoltages, phase sequence, and 

phase loss for three-phase 3-wire or 4-wire power supplies with 
just one Unit. 
Switch setting for 3-phase 3-wire or 3-phase 4-wire power 
supply.

• Two SPDT output relays, 6 A at 250 VAC (resistive load). 

Separate outputs possible for overvoltages and undervoltages.

• World-wide power specifications supported by one Unit 

(switchable).

• Relay warning status easily monitoring using LED indicator.

• Easy wiring with ferrules

×

 2.5 mm

2

 solid or 2 

×

 1.5 mm

2

 standard ferrules.

• CE mark compliance certified by third party.

UL certification.

Model Number Structure

Model Number Legend

1. Basic Model

K8AB: Measuring and Monitoring Relays

2. Functions

PM:

Three-phase Phase-sequence Phase-loss Relay (Simultaneous upper and lower monitoring)

3. Rated Input Voltage

1:

115, 127, 133, 138, 200, 220, 230, 240 VAC

2:

220, 230, 240, 277, 380, 400, 415, 480 VAC

1

2 3

K8AB-

@@

www.samelectric.ru

Содержание K8AB-PA1

Страница 1: ...e power supply One SPDT output relay 6 A at 250 VAC resistive load World wide power specifications supported by one Unit switchable Relay warning status easily monitoring using LED indicator Easy wiri...

Страница 2: ...g value setting range Asymmetry rate 2 to 22 Operating value 100 operation at set value Asymmetry operating value Rated input voltage x Asymmetry set value The asymmetry operation will function when t...

Страница 3: ...and exposed uncharged parts 20 M at 500 V between any charged terminals i e between input output and power supply terminals Degree of protection Terminal section IP20 Rear case IP40 Case color Munsel...

Страница 4: ...erating Voltage Asymmetry operation condition Highest voltage Lowest voltage Asymmetry operating voltage Asymmetry operating voltage Rated input voltage V Asymmetry set value Note The rated input volt...

Страница 5: ...ng mode OFF ON 3 phase 4 wire power monitoring mode SW3 SW4 Function Default 3 phase 3 wire mode 3 phase 4 wire mode SW3 SW4 OFF OFF Rated input voltage switch K8AB PA1 200 VAC 115 VAC OFF OFF ON OFF...

Страница 6: ...of the product 3 Do not use thinner or similar solvent for cleaning Use commercial alcohol 4 When discarding properly dispose of the product as industrial waste 5 Only use this product within a board...

Страница 7: ...power supplies One SPDT output relay 6 A at 250 VAC resistive load Relay warning status easily monitoring using LED indicator Easy wiring with ferrules 2 2 5 mm2 solid or 2 1 5 mm2 standard ferrules...

Страница 8: ...K8AB PH1 Rated input voltage Non isolated 200 to 500 VAC 15 VA Phase sequence phase loss operating time 0 1 s max value when rated operating voltage changes quickly from 0 to 100 Relays are normally O...

Страница 9: ...uncharged parts 20 M at 500 V between any charged terminals i e between input output and power supply terminals Degree of protection Terminal section IP20 Rear case IP40 Case color Munsell 5Y8 1 ivory...

Страница 10: ...y operative Nomenclature Front Indicators Dimensions L1 L2 L3 L1 L3 L2 L3 L2 L1 L1 L2 L3 Relay Phase Loss Operation Phase Sequence Operation Input Load Alarm Input Output L1 L2 L3 L3 L2 L1 The power s...

Страница 11: ...the product 3 Do not use thinner or similar solvent for cleaning Use commercial alcohol 4 When discarding properly dispose of the product as industrial waste 5 Only use this product within a board wh...

Страница 12: ...istive load Separate outputs possible for overvoltages and undervoltages World wide power specifications supported by one Unit switchable Relay warning status easily monitoring using LED indicator Eas...

Страница 13: ...e setting range Overvoltage 30 to 25 of maximum rated input voltage Undervoltage 30 to 25 of maximum rated input voltage Note The rated input voltage is switched with a switch Operating value 100 oper...

Страница 14: ...posed uncharged parts 20 M at 500 V between any charged terminals i e between input output and power supply terminals Degree of protection Terminal section IP20 Rear case IP40 Case color Munsell 5Y8 1...

Страница 15: ...L1 L2 L3 N L1 L2 L3 The power supply is shared with the rated in put voltage 14 12 11 24 22 21 Over voltage alarm Load Undervoltage alarm phase loss phase se quence alarm Power indicator Relay status...

Страница 16: ...itoring mode OFF ON 3 phase 4 wire power monitoring mode SW3 SW4 Function Default 3 phase 3 wire mode 3 phase 4 wire mode SW3 SW4 OFF OFF Rated input voltage switch K8AB PM1 200 VAC 115 VAC OFF OFF ON...

Страница 17: ...product 3 Do not use thinner or similar solvent for cleaning Use commercial alcohol 4 When discarding properly dispose of the product as industrial waste 5 Only use this product within a board whose...

Страница 18: ...sible for overvoltages and undervoltages World wide power specifications supported by one Unit switchable Relay warning status easily monitoring using LED indicator Easy wiring with ferrules 2 2 5 mm2...

Страница 19: ...d undervoltage Operating value setting range Overvoltage 30 to 25 of maximum rated input voltage Undervoltage 30 to 25 of maximum rated input voltage Note The rated input voltage is switched with a sw...

Страница 20: ...harged parts 20 M at 500 V between any charged terminals i e between input output and power supply terminals Degree of protection Terminal section IP20 Rear case IP40 Case color Munsell 5Y8 1 ivory Ca...

Страница 21: ...Over voltage alarm Under voltage alarm Load The power supply is shared with the rated in put voltage Power indicator Relay status indicator Overvoltage knob OVER Undervoltage knob UNDER Operating time...

Страница 22: ...phase 4 wire power monitoring mode SW3 SW4 Function Default 3 phase 3 wire mode 3 phase 4 wire mode SW3 SW4 OFF OFF Rated input voltage switch K8AB PW1 200 VAC 115 VAC OFF OFF ON OFF 220 VAC 127 VAC...

Страница 23: ...3 Do not use thinner or similar solvent for cleaning Use commercial alcohol 4 When discarding properly dispose of the product as industrial waste 5 Only use this product within a board whose structure...

Отзывы: