28
•
Input and Display Values
Input type
Setting range
Default
DC voltage input
–19999 to 99999
Input value 2
199.99
Display value 2
199.99
Input value 1
–199.99
Display value 1
–199.99
DC current input
–19999 to 99999
Input value 2
199.99
Display value 2
199.99
Input value 1
–199.99
Display value 1
–199.99
AC voltage input
–19999 to 99999
Input value 2
400.0
Display value 2
400.0
Input value 1
0.0
Display value 1
0.0
AC current input
–19999 to 99999
Input value 2
10.000
Display value 2
10.000
Input value 1
0.000
Display value 1
0.000
•
Decimal Point Position
Input type
Setting range
Default
DC voltage input
%%%%%
(without decimal point)
%%%.%%
DC current input
%.%%%%
%%%.%%
AC voltage input
%%.%%%
%%%.%%
%%%%.%
AC current input
%%%.%%
%%%%.%
%%.%%%
Refer to 5-1 Teaching Function for scaling the Process Meter with the sensor
connected.
Follow the steps described below to input the following.
Input value 2 = “5.00”
Display value 2 = “1000.0”
Input value 1 = “1.00”
Display value 1 = “0.0”
Decimal point position = “– – – – . –”
Set Value LED Display Model
Basic Model
1, 2, 3...
1. Press the Mode Key for more than one second while the
scale
scaling menu
is displayed. The
inp.2
input value 2 setting will appear.
Set Value LED Display Model
Basic Model
SETTING
REFERENCE
SETTING
EXAMPLE
Setting Mode
Section 3-2
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]