AMR Lock-out Tag-out Procedure
Use the following procedure to execute Lock-out Tag-out before performing any maintenance or instal-
lation work on the AMR.
WARNING
Do not perform maintenance work on the AMR until the measured voltage of the mo-
tor controller capacitors are below 7 VDC.
1
Press an E-STOP button.
2
Shut down the AMR by pressing the OFF button on the Operator Panel.
3
Turn the AMR main disconnect switch to OFF position (horizontal).
4
Lock and tag the main disconnect switch according to your facility requirement and regulations.
5
Probe the appropriate connector pins on the module shown below using a digital multimeter.
Probe the back of the pin 4 (positive) and pin 3 (negative).
Each motor controller is equipped with a capacitor that stores energy. You must check and
make sure that the voltage is less than 7 VDC.
6
After the voltage is less than 7 VDC, verify that the AMR is de-energized by pressing the ON /
OFF button on the Operator Panel and then repeat step 5.
After confirming the voltage remains less than 7 VDC, this procedure is complete.
6 Maintenance
6-4
HD-1500 Platform User's Manual (I645)
Содержание HD-1500 Platform
Страница 1: ...HD 1500 Platform User s Manual I645 E 03 ...
Страница 6: ...Manual Information 4 HD 1500 Platform User s Manual I645 ...
Страница 38: ...Revision History 36 HD 1500 Platform User s Manual I645 ...
Страница 206: ...5 Troubleshooting 5 14 HD 1500 Platform User s Manual I645 ...
Страница 236: ...6 Maintenance 6 30 HD 1500 Platform User s Manual I645 ...
Страница 250: ...Appendices A 14 HD 1500 Platform User s Manual I645 ...
Страница 251: ...I Index I 1 HD 1500 Platform User s Manual I645 I ...
Страница 254: ...Index I 4 HD 1500 Platform User s Manual I645 ...
Страница 255: ......