Specifications
Specifications are subject to change without prior notice.
* For children under 9 years old: Only weight and BMI will be displayed.
For people over 81 years old: The body composition can be measured for reference only.
Product
Body Composition Monitor HBF-701 (HBF-701-IN)
Display *
Display of Minimum Body Weight 0 to 100 kg with an increment of 100 g
100 to 135 kg with an increment of 200 g
BMI
2.5 to 90.0 with an increment of 0.1
Visceral Fat Level
0.5 to 30.0 levels with an increment of 0.5 level
Visceral Fat Level Classification 0 (Normal) / + (High) / ++ (Very High)
Body Age
18 to 80 with an increment of 1 year
Same Age Comparison
Segmental subcutaneous fat percentage : 5 levels
Segmental skeletal muscle percentage : 5 levels
Object age:
Over 18
years old
~
80 years old
or less
Resting Metabolism
385 to 3999 kcal with an increment of 1 kcal
Body Fat Percentage
5.0 to 50.0% with an increment of 0.1%
Body Fat Percentage Classification - (Low) / 0 (Normal) / + (High) / ++ (Very High)
Segmental Subcutaneous Fat Percentage
(Whole Body,Trunk,Legs,Arms)
5.0 to 60.0% with an increment of 0.1%
Segmental Skeletal Muscle Percentage
Whole Body • Arms
5.0 to 60.0% with an increment of 0.1%
Trunk
5.0 to 50.0% with an increment of 0.1%
Legs
5.0 to 70.0% with an increment of 0.1%
Progress Chart
4 levels
Object age:
Over 10
years old
~
80 years old
or less
Memory
Today / 1 day ago / 7 days ago / 1 month ago / 2 months ago / 3 months ago
Setting Items
Date
January 1, 2014 - December 31, 2030
Time
0:00 - 23:59 (24-hour display)
Set Personal Data (personal data of 4 persons can be set for the following items)
Date of Birth
January 1, 1900 - December 31, 2030
Gender
Male / Female
Height
100.0 to 199.5 cm with an increment of 0.5 cm
Age (when using GUEST mode) 10 to 99 years old with an increment of 1 year old
* When using GUEST mode, personal data should be set before each measurement.
Weight Measurement
Accuracy
0.0 kg to 40.0 kg:
±400 g
40.1 kg to 135.0 kg: ±1%
Power Supply
4 AA manganese batteries (R6)
[You can also use AA alkaline batteries (LR6)]
Battery Life
Approximately 1 year (using AA manganese batteries at room temperature
of 23˚C when measurement is taken for 4 times per day)
Operation Temperature
and Humidity
+5 - +35˚C; 30 - 85% RH
Storage Temperature /
Humidity / Air Pressure
-20 - +60˚C, 10 - 95% RH, 700 - 1060 hPa
Within well ventilated and dry room and no corrosive gas in surrounding air.
Type of Protection
Against Electric Shock
BF type for applied part. symbol:
Weight
Approximately 2.2 kg (including batteries)
External Dimensions
Approximately 325 mm (L) × 300 mm (W) × 51 mm (H)
Accessories
Batteries for trial use (4 AA manganese batteries),