H7HP

Safety Precautions (Common)

Note:

The undermentioned is common for all H7GP/H7HP models.

Precautions for Safe Use 

Observe the following items to ensure the safe use of this product. 

Environmental Precautions 

Store the H7GP/H7HP within the specified ratings. If the H7GP/
H7HP has been stored at temperatures 

10

°

C or lower, let it stand 

for 3 hours or longer at room temperature before turning ON the 
power supply.

Use the H7GP/H7HP within the specified ratings for operating 
temperature and humidity. 

Do not operate the H7GP/H7HP in locations subject to sudden or 
extreme changes in temperature, or locations where high humidity 
may result in condensation. 

Do not use the H7GP/H7HP in locations subject to vibrations or 
shock. Extended use in such locations may result in damage due to 
stress.

Do not use the H7GP/H7HP in locations subject to excessive dust, 
corrosive gas, or direct sunlight. 

Install the H7GP/H7HP well away from any sources of static 
electricity, such as pipes transporting molding materials, powders, 
or liquids.

The H7GP/H7HP is not waterproof or oil resistant. 
Do not use it in locations subject to water or oil.

The life expectancy of internal components may be reduced if the 
H7GP/H7HP is mounted side-by-side.

Do not use organic solvents (such as paint thinner or benzine), 
strong alkaline, or strong acids because they will damage the 
external finish. 

Usage Precautions 

Install a switch or circuit breaker that allows the operator to 
immediately turn OFF the power, and label it to clearly indicate its 
function.

Be sure to wire the terminals correctly.

Do not install input lines in the same duct or conduit as power 
supply or other high-voltage lines. Doing so may result in 
malfunction due to noise. Separate the input lines from high-
voltage lines. 

Internal elements may be destroyed if a voltage outside the rated 
voltage is applied. 

Maintain voltage fluctuations in the power supply within the 
specified range. 

Use a switch, relay, or other contact so that the rated power supply 
voltage will be reached within 0.1 s. If the power supply voltage is 
not reached quickly enough, the H7GP/H7HP may malfunction or 
outputs may be unstable. 

Although the H7GP/H7HP power supply (primary side) is isolated 
from control circuits (secondary side) by a transformer, the primary 
and secondary sides of the transformer are linked by a capacitor, 
making it possible for high-frequency components to leak to the 
secondary side. Take adequate precautions against electrical 
shock. Do not connect input circuits to exposed parts (such as the 
machine body) and be sure that the power supply is turned off 
before wiring.

Flush Mounting

The panel surface is water-resistive (conforming to NEMA 4 and 
IP66). In order to prevent the internal circuit from water penetration 
through the space between the counter and operating panel, attach a 
rubber packing between the counter and operating panel and secure 
the rubber packing with the Y92F-3

@

 flush-mounting adaptor.

Be sure the rubber packing is installed in the correct direction. The 
wider portion must be facing the panel when installed, as shown in 
the following illustration. Using a flat-head screwdriver, press in the 
Mounting Adapter until it cannot be pressed in any further in order to 
ensure water-resistive performance.

Other

Oil resistance is not applicable to all types of oil. Be sure to test any 
specific oils before actual application.

This may occasionally cause electric shock, fire, or malfunction.
Never disassemble, repair, or modify the H7GP/H7HP.

This may occasionally cause electric shock, fire, or malfunction.
Do not allow metal fragments or lead wire scraps to fall inside the 
H7GP/H7HP.

!

CAUTION

Control
circuit

Display 
circuit

Input
circuit

Adapter

Panel

Wider portion 
facing panel

Содержание H7HP -

Страница 1: ...cklight at low power consumption Compact 66 mm body Switch 6 digit models between total counter and time counter operation Model Number Structure Model Number Legend 1 Classification A Total counter t...

Страница 2: ...gh characters Function Total counter time counter selected via DIP switch Total counter Input mode Up down individual total counter or accumulative time counter Up down individual Max counting speeds...

Страница 3: ...ch in three directions 8 minutes per cycle Malfunction 10 to 55 Hz with 0 5 mm single amplitude four cycles each in three directions 8 minutes per cycle Shock resistance Destruction 294 m s2 each in t...

Страница 4: ...de PNP mode Unused Unused Unused Unused Unused NPN mode PNP mode 100 to 240 VAC Unused Unused Unused 12 to 24 VDC NPN mode PNP mode Unused Unused H7HP C8 H7HP C8D DC Models H7HP AD External power supp...

Страница 5: ...e will return to 0 when 999999 is exceeded Note 1 Display values are shown for full scale set to 99999 9 h The count value will return to 0 when 99999 9 is exceeded 2 Gate input is available only when...

Страница 6: ...anel Cutouts With Flush Mounting Bracket Terminal cover provided Panel M3 5 terminal screw H7HP A H7HP C8 Panel cutouts are as shown below according to DIN43700 Note 1 The mounting panel thickness sho...

Страница 7: ...or 0 short circuit Approx 2 mA Open OFF impedance 100 k min Key protection input Short circuit ON impedance 1 k max Short circuit ON residual voltage 0 5 VDC max Current flow for 0 short circuit Appro...

Страница 8: ...e input lines from high voltage lines Internal elements may be destroyed if a voltage outside the rated voltage is applied Maintain voltage fluctuations in the power supply within the specified range...

Страница 9: ...GP H7HP and DIP switch labels are included with the H7HP Attach these labels as shown in the following illustrations Display Error Correction Less than 99999 H7HP 6 digit model Less than 99999999 H7HP...

Страница 10: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control syste...

Отзывы: