background image

http://www.ia.omron.com/

2

(c)Copyright OMRON Corporation 2007   All Rights Reserved. 

H7HP

Specifications

Ratings

Note: 1.

Contains 20% ripple (p-p) max.

2.

Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even
if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be
functional.

Item

6-digit total counter/time counter

8-digit total counter

H7HP-A

H7HP-AD

H7HP-C8

H7HP-C8D

Rated supply voltage

100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1)

External power supply

50 mA at 12 VDC

---

50 mA at 12 VDC

---

Operating voltage range

85% to 110% of rated supply voltage

Power consumption

100 to 240 VAC: 6.5 VA max.
12 to 24 VDC:

0.6 W max.

Dimensions

72 x 36 x 66 mm (W x H x D)

Mounting method

Flush mounting

External connections

Screw terminals

Degree of protection

Panel surface: IEC IP66 (JEM standard IP66G) and NEMA Type 4 (indoors)

Display

7-segment, negative transmissive LCD (with red backlight)

Digits

6 digits (15-mm-high characters)

8 digits (12-mm-high characters)

Function

Total counter/time counter (selected via DIP switch)

Total counter

Input mode

Up/down (individual) (total counter), or accumulative 
(time counter)

Up/down (individual)

Max. counting speeds

30 Hz or 5 kHz (selected via DIP switch)

Counting range

–99999 to 999999

–9999999 to 99999999

Time specification

0.1 to 99999.9 h/1 s to 99 h 59 min 59 s

---

Timing accuracy

±

100 ppm (–10

°

C to 55

°

C)

---

Memory backup

EEP-ROM: 200,000 operations min.

Input

Input signals

Count 1/start, count 2/gate, reset, and key protection (see note 2)

Input method

No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected via DIP switch)

Count, start, 
gate, reset

No-voltage input (NPN transistor input)

Short-circuit (ON) impedance:

1 k

Ω

 max.

Short-circuit (ON) residual voltage:  2 VDC max.
Open (OFF) impedance:

100 k

Ω

 min.

Voltage input (PNP transistor input)

Short-circuit (ON) impedance:

1 k

Ω

 max.

ON voltage:

9 to 24 VDC 

OFF voltage:

5 VDC max.

Open (OFF) impedance:

100 k

Ω

 max.

Key protection

No-voltage input (NPN transistor input)

Short-circuit (ON) impedance:

1 k

Ω

 max.

Short-circuit (ON) residual voltage: 0.5 VDC max.
Open (OFF) impedance:

100 k

Ω

 min.

Input re-
sponse 
speed

Reset

Time counter: 20 ms; total counter: 20 ms or 1 ms (automatically switched according to counting speed)

Start

Time counter: 20 ms

Key protection

Approx. 1 s

Approx. 1 s

Reset system

External and manual resets

Содержание H7HP -

Страница 1: ...cklight at low power consumption Compact 66 mm body Switch 6 digit models between total counter and time counter operation Model Number Structure Model Number Legend 1 Classification A Total counter t...

Страница 2: ...gh characters Function Total counter time counter selected via DIP switch Total counter Input mode Up down individual total counter or accumulative time counter Up down individual Max counting speeds...

Страница 3: ...ch in three directions 8 minutes per cycle Malfunction 10 to 55 Hz with 0 5 mm single amplitude four cycles each in three directions 8 minutes per cycle Shock resistance Destruction 294 m s2 each in t...

Страница 4: ...de PNP mode Unused Unused Unused Unused Unused NPN mode PNP mode 100 to 240 VAC Unused Unused Unused 12 to 24 VDC NPN mode PNP mode Unused Unused H7HP C8 H7HP C8D DC Models H7HP AD External power supp...

Страница 5: ...e will return to 0 when 999999 is exceeded Note 1 Display values are shown for full scale set to 99999 9 h The count value will return to 0 when 99999 9 is exceeded 2 Gate input is available only when...

Страница 6: ...anel Cutouts With Flush Mounting Bracket Terminal cover provided Panel M3 5 terminal screw H7HP A H7HP C8 Panel cutouts are as shown below according to DIN43700 Note 1 The mounting panel thickness sho...

Страница 7: ...or 0 short circuit Approx 2 mA Open OFF impedance 100 k min Key protection input Short circuit ON impedance 1 k max Short circuit ON residual voltage 0 5 VDC max Current flow for 0 short circuit Appro...

Страница 8: ...e input lines from high voltage lines Internal elements may be destroyed if a voltage outside the rated voltage is applied Maintain voltage fluctuations in the power supply within the specified range...

Страница 9: ...GP H7HP and DIP switch labels are included with the H7HP Attach these labels as shown in the following illustrations Display Error Correction Less than 99999 H7HP 6 digit model Less than 99999999 H7HP...

Страница 10: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control syste...

Отзывы: