No.14S002-08
23/53
STC-SBE132POE / STC-SCE132POE
Product Specifications and User’s Guide
Exposure Timing with the Positive Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 60 CLK.
Please input a trigger signal with more than 61 CLK pulse width.
Note 2: The exposure will start 10us after the rising edge of the trigger signal.
Exposure Timing with the Negative Polarity Trigger signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 60 CLK.
Please input a trigger signal with more than 61 CLK pulse width.
Note 2: The exposure will start 10us after the rising edge of the trigger signal.
Input Trigger signal
Exposure time
T1'
Exposure tim: T1' = Preset exposure time
Filtering *Note.1
60 CLK
Less than
60 useconds
Trigger signal
(With Photocoupler delay
10us
Input Trigger signal
Exposure time
T1'
Exposure tim: T1' = Preset exposure time
Filtering *Note.1
60 CLK
Less than
15useconds
Trigger signal
(With Photocoupler delay
10us