Multi-channel Power Controller
G3ZA
3
Specifications
■
Ratings
Note: 1.
CT inputs are provided only on Models with heater burnout detection.
2.
Use an SSR without the zero-cross function (G3PA-
@
BL-VD) for soft-start optimum cycle control. (Refer to page 11.)
■
Performance
Note:
When measured with percentage selected for the current monitor
parameter and the maximum current measurable with the CT at 100%.
■
Communications Specifications
■
Current Transformer Specifications
(Order Separately)
Note:
The maximum continuous current is 50 A for the G3ZA in combination
with the E54-CT3.
Item
Load power supply
voltage range
100 to 240 VAC
400 to 480 VAC
Power supply voltage
100 to 240 VAC (50/60 Hz)
Operating voltage range
85 to 264 VAC
Power consumption
16 VA max.
Load power supply voltage
100 to 240 VAC
400 to 480 VAC
Load power supply voltage range
75 to 264 VAC
340 to 528 VAC
Manipulated variable input
0.0% to 100.0% (via RS-485 communications)
Current transformer input (See note 1.)
Single-phase AC, 0 to 50 A (primary current of CT)
Single-phase AC, 0 to 150 A (primary current of CT)
Trigger output
One voltage output for each channel, 12 VDC
±
15%, Max. load current: 21 mA
(with built-in short-circuit protection circuit)
Alarm output
NPN open collector, one output
Max. applicable voltage: 30 VDC, Max. load current: 50 mA
Residual voltage: 1.5 V max., Leakage current: 0.4 mA max.
Indications
LED indicators
Control method
Optimum cycle control
Soft-start optimum cycle control (See note 2.)
Three-phase optimum cycle control
Ambient operating temperature
−
10 to 55
°
C (with no icing or condensation)
Ambient operating humidity
25% to 85%
Storage temperature
−
25 to 65
°
C (with no icing or condensation)
Elevation
2,000 m max.
Accessories
Instruction Sheet
V2
V2
V2
Current indication
accuracy
Current Range
0 to 50 A,
±
3 A
0 to 150 A, ±9 A
0 to 100%, ±6% (See note.)
(for models with heater burnout detection)
Insulation resistance
100 M
Ω
min. (at 500 VDC) between primary and
secondary
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between primary
and secondary
Vibration resistance
Vibration frequency: 10 to 55 Hz,
acceleration: 50 m/s
2
in X, Y, and Z directions
Shock resistance
300 m/s
2
three times each in six directions along
three axes
Weight
Approx. 200 g (including terminal cover)
Degree of protection
IP20
Memory protection
EEPROM (non-volatile memory) (number of
writes: 100,000)
Installation environment
Overvoltage category III,
pollution degree 2 (according to IEC 60664-1)
Approved standards
UL508 (Listing), CSA22.2 No. 14
EN50178
EN61000-6-4 (EN55011: 1998, A1: 1999 Class A,
Group 1)
EN61000-6-2: 2001
Transmission line connections
Multipoint
Communications method
RS-485
Max. transmission distance
500 m
No. of nodes
31 (via multidrop connections)
Synchronization method
Stop-start synchronization
Communications baud rate
9.6, 19.2, 38.4 or 57.6 kbps,
Default: 9.6 kbps
Transmission code
ASCII
Communications data length
7 or 8 bits, Default: 7
Communications stop bits
1 or 2 bits, Default: 2
Communications parity
Vertical parity: None, even, or odd,
Default: Even
Flow control
None
Item
Specification
Model number
E54-CT1
E54-CT3
G3ZA-CT150L
Max. continuous
heater current
50 A
120 A (See note.)
150 A
Detection current
with G3ZA
connected
50 A
150 A
Dielectric strength
1,000 VAC for 1 min
2,000 VAC for 1
min
Vibration resistance
98 m/s
2
, 50 Hz
Weight
Approx. 11.5 g Approx. 50 g
Approx. 130 g
Accessories
None
Connection
terminals (2)
Plugs (2)
None
Содержание G3ZA
Страница 17: ...Solid State Relays G3PA 17 ...
Страница 18: ...18 Solid State Relays G3PA ...
Страница 19: ...Solid State Relays G3PA 19 ...