Definition of Precautionary Information

Precautions for Safe Use

Transpporting

Do not use or store the G3RV in the following transporting.
of Doing so may result in damage, mulfunction, or detericration 
of performance characteristics.

Conditions under which the G3RV will be exposed to water.

High temperatures or high humidity.

Without proper packing.

Operating and Strage Locations

Do not use or store the G3RV, in the following locations. Doing so 
may result in damage, mulfunction, or detericration of 
performance characteristic.

Locations subject to rain or water drops.

Locations subject to exposure to water, or oil, or chemicals.

Locations subject to high temperatures or high humidity.

Locations subject to ambient temperatures outside the range 
from -30 to +100 centigrade.

Locations subject to relative humidity outside the range 45% to 
85%.

Locations subject to corrosive or ammable gasses.

Locations subject to dust (especially iron dust) or salts.

Locations subject to barrier.

Handring

Must need an air convection for G3RV or the heat convection air 
producess a heating on G3RV abnormal and causes a 
short-circuit failure and burning.

Do not use the G3RV with terminal bending due to dropping etc. 
Bent terminal may poorly tting electrical contacts, leading to 
trouble.

Do not carry out the mounting work with hand stained with oil or 
metal powder. Otherwise, trouble may be caused.

Mounting

Mount the G3RV in the speci ed orientation. If the G3RV is 
mounted in any other orientation, abnormal heat generation 
may cause output elements to short or may cause burning.

Be sure to prevent the ambient temperature from rising due to 
the heat radiation of the G3RV. If the G3RV is mounted a panel, 
install a fan so that the interior of the panel is fully inside 
ventilated.

Be sure that the G3RV clicks into place when mounting it to DIN 
Track. The G3RV may fall if it is not mounted correctly.

Wiring

Use a wire an adequate size for current to be applied. Abnormal 
heating of wire may cause burning.

Do not use any wires with damaged sheaths. These may caus 
electric shock leakage.

Con rm it wire for G3RV is not used in pipe or duct for high 
voltage power supply.Induction will be generated and cause 
malfunction or damages.

Be sure to conduct wiring with the power supply turned OFF. 
Touching the terminals when they are charged may occationally 
result in minor electric shock.

Using

Select a load within the rated range. Inappropriate load may 
cause misoperation, trouble or burning.

Select the power supply within the rated frequency range. 
Inappropriate power frequency may cause misoperation, trouble 
or burning.

Precautions for Correct Use

G3RV uses electronics parts mounting on PCB, so that any 
dropping and vibration, physical shock beyond the standard level 
should beprevented, otherwise the initial characteristic will be not 
injured.

Terminal screw must be tightened with regulation torque. Less 
convection air produces a heating on G3RV abnormal and causes 
a short-circuit failure and burning. 
(M2.5, 0.4 N•m)

Do not supply a high voltage/current to the input and output. Short 
circuit failure or burning must be occured on G3RV.

Do not use or store the G3RV, in the following locations. Doing so 
may result in damage, malfunction, or deterioration of 
performance characteristic.

Locations subject to static electricity or other forms of noise.

Locations subject to strong electromagnetic elds.

Locations subject to possible exposure to radioactivity.

WARNING

Indicates a potentially hazardous situation which, 
if not avoided, will result in minor or moderate 
injury, or may result in serious injury or death. 
Additionally there may be significant property 
damage.

CAUTION

A potentioally hazardous situation by misuse, 
may result in property damage only accident. 

CAUTION

Minor hazard by electric shock may occasionally occur. 
Do not touch the G3RV's terminal (Charging part) while 
the power supply turned on.

The G3RV may occasionally rupture in case of a short 
circuit.
To protect against short-circuit accident, install a 
protective device, such as a quick-burning fuse or a 
circuit breaker or the like, on the power supply.

Minor hazard by electric shock may occasionally occur. 
Do not touch the G3RV's main circuit terminals 
immediately after the power is turned OFF. 
The internal snubber circuit is charged. 

*

 202S,SL,G3RV-A(L) Type only

Minor hazard by burns may occasionally occur. 
Do not touch the G3RV or the heat sink either while the 
power supply is ON, or immediately after the power is 
turned OFF.
The G3RV and the heat sink will be hot.

Содержание G3RV

Страница 1: ...G3RV SL Classification Enclosure rating Input voltage Type of connection Contact form SPST Plug in terminals General purpose Unsealed AC DC Screw terminals G3RV SL700 Push in terminals G3RV SL500 Inp...

Страница 2: ...VDC 12 mA 21 6V 24 VAC DC 20 mA 21 mA 11 mA 21 6V 48 VAC DC 10 mA 11 mA 6 mA 43 2V 110 VAC 7 5 mA 8 2 mA 99V 230 VAC 7 3 mA 8 6 mA 207V Rated voltage Rated current Must operate voltage Must release vo...

Страница 3: ...icing or condensation Operating 30 55 C with no icing or condensation Ambient humidity 45 85 RH Weight Approx 38 g Pollution degree 2 Degree of protection according to IEC 60529 IP20 Rated Impulse Wit...

Страница 4: ...e Current Non repetitive Non repetitive Keep the inrush current to half the rated value if it occurs repetitively The values shown by the solid line are for non repetitive inrush currents Mounting Dis...

Страница 5: ...tion Connection P2RVC 8 O F PLC Output Interface for 8x G2RV SL700 G3RV SL700 series PNP type Ribbon cable connector 10 Pole IEC603 1 Input Rated voltage 30 VAC VDC max Current capacity 0 5 A per chan...

Страница 6: ...Green DC12V AC Yes 2A at 100 to 240VAC G3RV 202S DC12 G3RV SL700 500 A DC12 DC24V G3RV 202S DC24 G3RV SL700 500 A DC24 AC DC24V G3RV SL700 500 A AC DC24 AC DC48V G3RV SL700 500 A AC DC48 AC110V G3RV...

Страница 7: ...minimum order Red R Blue S Black B P2RVM 030 3 60 pcs box minimum order P2RVM 040 4 60 pcs box minimum order P2RVM 100 10 20 pcs box minimum order P2RVM 200 20 20 pcs box minimum order Max current EN...

Страница 8: ...n P2RV S 50 plates Provides isolation between adjacent relays to achieve 400 V isolation Five M2 5 6 6 2 max 99 2 7 1 88 9 26 1 47 2 70 9 83 106 7 max 92 7 max 35 Input circuit 24 V DC Terminal Arrang...

Страница 9: ...ew Other Input Voltage Terminal Arrangement Internal Connections Top View 12 V DC Terminal Arrangement Internal Connections Top View 6 2 max 99 2 88 9 7 1 24 6 46 69 8 82 9 106 7 max 97 4 max 35 G3RV...

Страница 10: ...tool Applicable Wires Applicable Wire Sizes G3RV SL700 Series Box clamp technology G3RV SL500 Series Push in technology Tightening torque G3RV SL700 Series 0 4Nm 2 5 dia 3 0 mm max Cannot be used Fla...

Страница 11: ...conductor into the connection hole No other tools are required Note In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire Screwdriver should be re...

Страница 12: ...e to connect cables properly if the screwdriver is inserted incorrectly General Precautions Do not use the product if it has been dropped on the ground Dropping the product may adversely affect perfor...

Страница 13: ...Induction will be generated and cause malfunction or damages Be sure to conduct wiring with the power supply turned OFF Touching the terminals when they are charged may occationally result in minor el...

Страница 14: ...ducts in the customer s application or use of the product Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it will be used Know an...

Отзывы: