manualshive.com logo in svg
background image

GigaVUE TA Series

Hardware Installation

Guide

GigaVUE TA Series

Product Version: 5.12

Document Version: 2.0

(See Change Notes for document updates.)

Содержание GigaVUE H TA100-CXP

Страница 1: ...GigaVUE TA Series Hardware Installation Guide GigaVUE TA Series Product Version 5 12 Document Version 2 0 See Change Notes for document updates ...

Страница 2: ...nscribed translated into any language stored in a retrieval system or transmitted in any form or any means without the written permission of Gigamon Inc Trademark Attributions Gigamon and the Gigamon logo are trademarks of Gigamon in the United States and or other countries Gigamon trademarks can be found at www gigamon com legal trademarks All other trademarks are the trademarks of their respecti...

Страница 3: ...ovide a link to this Change Notes table which will describe the updates Product Version Document Version Date Updated Change Notes 5 12 00 2 0 05 21 2021 Post release update to address priority bugs Updated Power Requirements section Updated password details Access the Command Line Interface over the console Port 5 12 00 1 0 04 15 2021 Original release of this document with 5 12 00 GA ...

Страница 4: ...is 16 GigaVUE TA25 Ports and Description 17 Chassis Cooling 17 Power LED 19 System LED 20 Fan LED 20 PSU LEDs 20 GigaVUE TA25 Rules and Notes 20 AMI_BIOS_Images 21 Air Flows Directions 22 AC and DC Powered GigaVUE TA25 Models 22 Battery Caution 22 GigaVUE TA Series TA40 Chassis 22 Air Flow Direction 24 AC and DC Powered GigaVUE TA Series TA40 Models 24 GigaVUE TA Series TA100 Chassis 24 Chassis Co...

Страница 5: ...ftware Upgrade using USB Drive 39 Air Flow Direction 39 AC and DC Powered GigaVUE TA Series TA100 CXP Models 39 Battery Caution 39 GigaVUE TA Series TA200 Chassis 39 Chassis Cooling 43 Power LEDs 45 System LED 45 Port Status LEDs 45 Global Fan LED 46 Individual Fan LEDs 46 Individual Power LEDs 46 GigaVUE TA Series TA200 Notes and Rules 46 AMI BIOS Images 47 Air Flow Direction 48 AC and DC Powered...

Страница 6: ...es TA100 70 GigaVUE TA Series TA200 70 GigaVUE TA25A 70 Enabling Additional Ports 71 Advanced Features Licensing 72 Command Line Basics 72 Command Line Modes 72 Entering Commands in the CLI 73 The Basic Commands 76 Completing the Initial Setup 79 Enter the Configure Command Line Mode 79 SSH2 79 Initial User Account Configuration 81 Configuring the GigaVUE TA Series TA Series Host Name 83 Configuri...

Страница 7: ... Regulatory Labels 101 GigaVUE TA Series TA10 102 GigaVUE TA Series TA40 102 GigaVUE TA Series TA100 103 GigaVUE TA Series TA100 CXP 103 GigaVUE TA Series TA200 104 GigaVUE TA25 104 NEBS Level 3 Compliance 105 Installation Instructions GigaVUE TA Series TA10 TA40 TA100 TA200 105 Intrabuilding or Intra connection for GigaVUE TA Series TA10 105 Intrabuilding or Intra connection for GigaVUE TA Series...

Страница 8: ...y port density and from 1Gb up to 100Gb support The GigaVUE H Series and GigaVUE TA Series include the following models that run GigaVUE OS GigaVUE HC1 GigaVUE HC2 GigaVUE HC3 GigaVUE TA Series TA10 GigaVUE TA Series TA40 GigaVUE TA Series TA100 GigaVUE TA Series TA100 CXP GigaVUE TA Series TA200 GigaVUE TA25 Certified Traffic Aggregation White Boxes GigaVUE TA SeriesOverview Gigamon s TA Series n...

Страница 9: ... nodes including both GigaVUE H Series nodes or G Series for example a GigaVUE TA Series 2404 node a GigaVUE TA Series HD8 node Featured topics GigaVUE TA Series Nodes GigaVUE TA Series includes the following models GigaVUE TA Series TA10 GigaVUE TA Series TA40 Contents 9 GigaVUE TA Series Hardware Installation Guide ...

Страница 10: ...ports Optional patch or breakout panel support Cluster with H Series nodes GigaVUE TA Series TA100 1RU Footprint 32 100Gb 40Gb ports Optional patch or breakout panel support Cluster with H Series nodes GigaVUE TA Series TA100 CXP 1RU Footprint 20 100Gb CXP ports 8 100Gb 40Gb QSFP28 ports GigaVUE TA Series TA200 2RU Footprint 64 100Gb 40Gb ports Optional patch or breakout panel support Cluster with...

Страница 11: ...t is sent to the tools GigaVUE TA Series nodes offer the following features and benefits High density visibility for 1Gb 10Gb 25Gb 40Gb and 100Gb Low profile 1RU 2RU for GigaVUE TA Series TA200 design offers easy deployment at the top of rack or end of row in data centers Depending on the model the GigaVUE TA Series supports a wide variety of Gigamon transceivers Transceivers purchased from other ...

Страница 12: ...ts for proactive notification of a wide variety of GigaVUE TA Series node events helping you keep tabs on system status in real time Scalable Port Density The GigaVUE TA Series TA10 can have either twenty four 24 or forty eight 48 1Gb 10Gb ports enabled The 24 port GigaVUE TA Series TA10 is called the GigaVUE TA Series TA10A A license is available to expand the GigaVUE TA Series TA10A to include a...

Страница 13: ...ke other GigaVUE H Series GigaVUE TA Series TA10 Chassis This section describes the physical layout of the GigaVUE TA Series TA10 chassis including a description of all ports and connectors The GigaVUE TA Series TA10 chassis consists of a 1RU rack mountable 19 wide chassis with management network and tool ports at the front and power connections at the rear Figure 1The GigaVUE TA Series TA10 Chass...

Страница 14: ...Serial Console and Mgmt Ports on page 57 for information on establishing a SSH configuration session with the GigaVUE TA Series TA10 Traffic Aggregator Console Use the Console port for local configuration of the GigaVUE TA Series TA10 Traffic Aggregator over a serial connection Refer to Access the Command Line Interface Table 1 GigaVUE TA Series TA10 Ports Contents 14 GigaVUE TA Series Hardware In...

Страница 15: ...e on GigaVUE TA10 Once a 40Gb port has been configured to operate as four 10Gb ports cable it to an optical patch panel or breakout panel which takes a 40Gb QSFP input from the GigaVUE TA Series TA10 and splits it to four independent 10Gb output ports Refer to Breakout Panels The q1 q4 ports accept 40Gb QSFP connections using active fiber QSFP SR or PLR4 transceivers The q1 q4 ports accept 40Gb Bi...

Страница 16: ...ency of updating the power supply module information is reduced As a result GigaVUE TA Series TA10 PSU information displayed in the CLI output is not real time Introducing the GigaVUE TA25 Chassis The GigaVUE TA25 chassis consists of a 1RU rack mountable 19 wide chassis with network tool ports at the front and power connections management console ports at the rear Refer to GigaVUE TA25 Ports and D...

Страница 17: ...f the 100Gb 40Gb ports operate as four logical 25Gb 10Gb ports Once a 100Gb 40Gb port has been configured to operate as four 25Gb 10Gb ports cable it to an optical patch panel or breakout panel which takes a QSFP28 QSFP input from the GigaVUE TA25 and splits it to four independent 25Gb 10Gb output ports The c1 and c5 ports accept QSFP28 QSFP connections using 100G 40G SR and PLR4 transceivers Rese...

Страница 18: ...U temperatures intake temperature as well as the fan speed in RPM config show environment Box 1 TA25 Chassis Power Module 1 PWR TAX21 12v voltage 12 46 V 0 95v voltage N A Sense voltage N A Power Module 2 PWR TAX21 12v voltage 0 0 V 0 95v voltage N A Sense voltage N A Fan tray 1 FAN TAX20 1st fan 12061 RPM 2nd fan 12024 RPM Fan tray 2 FAN TAX20 1st fan 12061 RPM 2nd fan 11951 RPM Fan tray 3 FAN TA...

Страница 19: ... PN GMONQ85S NGM GMONC85S NGM SFP vendor SN INGBT8030260 INGBL5673819 SFP Power 1 2 dBm 3 66 3 63 0 05 0 69 SFP Power 3 4 dBm 40 00 40 00 0 02 0 48 SFP Power 5 6 dBm SFP Power 7 8 dBm SFP Power 9 10 dBm SFP Temperature C 28 00 30 00 Alarm THld H L dBm N A N A Alert THld H L dBm N A N A Power THld Status N A N A Comment Power LED The power LEDs on the front of the chassis PWR1 and PWR2 are as follo...

Страница 20: ...nd is receiving good AC input Solid AMBER indicates the PSU is not operational and is not receiving any AC input GigaVUE TA25 Rules and Notes Keep in mind the following notes and rules when using the GigaVUE TA25 GigaVUE TA25 Rules and Notes Transceivers All Gigamon labeled 1Gb 10Gb 25Gb 40Gb and 100Gb optics are supported For details about the supported transceiver cable type and connectivity spe...

Страница 21: ...S_Images The GigaVUE TA25 has an AMI Basic Input Output System BIOS The BIOS image is packaged with the software image The BIOS contents are stored in flash memory allowing the BIOS to be upgraded There are two flash components a primary and a secondary The following CLI command displays the two flash components and indicates the BIOS image from which the system booted using asterisks config show ...

Страница 22: ...ote the following There is a risk of fire if the battery is replaced with an incorrect type Use only CR 2032L type Lithium metal coin cell battery and replace with the same GigaVUE TA Series TA40 Chassis This section describes the physical layout of the GigaVUE TA Series TA40 chassis including a description of all ports and connectors The GigaVUE TA Series TA40 chassis consists of a 1RU rack mount...

Страница 23: ...t for local configuration of the GigaVUE TA Series TA40 Traffic Aggregator over a serial connection Ports q1 q32 GigaVUE TA Series TA40 includes 32 40Gb ports q1 q32 The 40Gb ports can be used as a 40Gb ingress port or as a high speed tool port for aggregated output to a matching 40Gb port on a GigaVUE TA Series H Series node Table 3 GigaVUE TA Series TA40 Ports Contents 23 GigaVUE TA Series Hardw...

Страница 24: ...ies TA40 Models Gigamon provides both AC and DC powered versions of the GigaVUE TA Series TA40 Refer to Connecting 48V DC Power Supplies GigaVUE TA Series TA100 Chassis This section describes the physical layout of the GigaVUE TA Series TA100 chassis including a description of all ports and connectors The GigaVUE TA Series TA100 chassis consists of a 1RU rack mountable 19 wide chassis with managem...

Страница 25: ...e running software version 4 8 or higher Figure 3 The GigaVUE TA Series TA100 Chassis Front View Port Description Mgmt Use the Mgmt port for remote configuration of the GigaVUE TA Series TA100 Traffic Aggregator over a 10 100 1000 Ethernet network Console Use the console port for local configuration of the GigaVUE TA Series TA100 Traffic Aggregator over a serial connection Table 4 GigaVUE TA Serie...

Страница 26: ...1 c2x1 For details refer to Configure the Port Mode Once a 40Gb port has been configured to operate as four 10Gb ports cable it to an optical patch panel or breakout panel such as PNL M341 which takes a 40Gb QSFP input from the GigaVUE TA Series TA100 and splits it to four independent 10Gb output ports Refer to Breakout Panels The ports accept 40Gb QSFP connections using QSFP SR or PLR4 transceive...

Страница 27: ...PU Temperature Switch CPU Temperature 70ºC Warning trap sent 85ºC Warning trap sent 90ºC Warning trap sent 105ºC Warning trap sent 80ºC Alert trap sent Transceiver power disabled 90ºC Alert trap sent 95ºC Alert trap sent 115ºC Alert trap sent Switch CPU put in reset 95ºC Critical trap sent 95ºC Critical trap sent 100ºC Critical trap sent 140ºC Critical trap sent The output of the following CLI com...

Страница 28: ...R indicates a Power On Self Test POST is in progress Blinking AMBER indicates that the PSU is present but without power Off indicates that the PSU is not inserted in the chassis System LED The system LED on the front of the chassis is as follows Off indicates no power Blinking GREEN indicates the node is booting or the system is in diagnostic mode Solid GREEN indicates normal operation Solid RED i...

Страница 29: ...MBER indicates one or more fans have failed Individual Fan LEDs The individual fan LEDs on the rear of the chassis are as follows GREEN indicates the fan is operating normally AMBER indicates the fan has failed Individual Power LEDs The individual power LEDs on the rear of the chassis are as follows GREEN indicates the PSU is operating normally Off indicates the PSU is not operational GigaVUE TA S...

Страница 30: ...to GigaVUE TA Series TA100 GigaVUE TA Series TA100 to GigaVUE TA Series TA100 Stack Links at 40Gb The GigaVUE TA Series TA100 can connect to all GigaVUE TA Series nodes that support 40Gb through a 40Gb stack link using SR4 and LR4 optics with the following exception PRT HC0 C02 on GigaVUE HC2 Stack Links at 100Gb The GigaVUE TA Series TA100 can connect to the following nodes modules and line cards...

Страница 31: ...components and indicates the BIOS image from which the system booted using asterisks config show version 1st flash version coreboot ta100 1 0 0 Wed Aug 23 16 10 34 CST 2017 2nd flash version coreboot ta100 1 0 0 Wed Aug 23 16 10 34 CST 2017 If there is a component failure in the primary flash the GigaVUE TA Series TA100 boots from a backup golden BIOS image in the secondary flash An SNMP trap can ...

Страница 32: ...and replace with the same GigaVUE TA Series TA100 CXP Chassis This section describes the physical layout of the GigaVUE TA Series TA100 CXP chassis including a description of all ports and connectors The GigaVUE TA Series TA100 CXP chassis consists of a 1RU rack mountable 19 wide chassis with management network and tool ports at the front and power connections and fans at the rear Figure 5The Giga...

Страница 33: ... TA100 CXP node must be running software version 5 0 or higher Figure 5 The GigaVUE TA Series TA100 CXP Chassis Front View Port Description Mgmt Use the Mgmt port for remote configuration of the GigaVUE TA Series TA100 CXP over a 10 100 1000 Ethernet network Console Use the console port for local configuration of the GigaVUE TA Series TA100 CXP over a serial connection Table 6 GigaVUE TA Series TA...

Страница 34: ... subports The subports will all have the same speed 10Gb Subports will have x1 to x4 appended to their port ID for example 1 1 c21x1 For details refer to Configure the Port Mode Once a 40Gb port has been configured to operate as four 10Gb ports cable it to an optical patch panel or breakout panel such as PNL M341 which takes a 40Gb QSFP input from the GigaVUE TA Series TA100 CXP and splits it to f...

Страница 35: ...ature Switch CPU Temperature 70ºC Warning trap sent 85ºC Warning trap sent 90ºC Warning trap sent 105ºC Warning trap sent 80ºC Alert trap sent Transceiver power disabled 90ºC Alert trap sent 95ºC Alert trap sent 115ºC Alert trap sent Switch CPU put in reset 95ºC Critical trap sent 95ºC Critical trap sent 100ºC Critical trap sent 140ºC Critical trap sent The output of the following CLI command disp...

Страница 36: ...BER indicates a Power On Self Test POST is in progress Blinking AMBER indicates that the PSU is present but without power Off indicates that the PSU is not inserted in the chassis System LED The system LED on the front of the chassis is as follows Solid GREEN indicates normal operation Blinking GREEN indicates the node is booting or the system is in diagnostic mode Solid RED indicates a critical a...

Страница 37: ...ER indicates the port is administratively disabled GREEN indicates the link is operationally up Global Fan LED The global fan LED on the front of the chassis is as follows Solid GREEN indicates all fans are operating normally Solid AMBER indicates one or more fans have failed Individual Fan LEDs The individual fan LEDs on the rear of the chassis are as follows Solid GREEN indicates the fan is oper...

Страница 38: ...tware image starting in software version 4 8 01 The BIOS contents are stored in flash memory allowing the BIOS to be upgraded There are two flash components a primary and a secondary The following CLI command displays the two flash components and indicates the BIOS image from which the system booted using asterisks config show version 1st flash version coreboot ta100cxp 1 0 0_20170110 Tues Jan 10 ...

Страница 39: ...ake air at the front of the chassis is cold AC and DC Powered GigaVUE TA Series TA100 CXP Models Gigamon provides both AC and DC powered versions of the GigaVUE TA Series TA100 CXP Battery Caution A disposable non rechargeable Real Time Clock RTC Lithium metal coin cell battery is in the GigaVUE TA Series TA100 CXP Note the following There is a risk of fire if the battery is replaced with an incor...

Страница 40: ...s supporting high density aggregation Depending on the transceiver QSFP or QSFP28 the ports run at speeds of either 40Gb or 100Gb With QSFP28 SR4 transceivers a 100Gb port can be broken out into four 25Gb ports called 4x25G mode With 40G SR4 40Gb ESR4 and PLR4 QSFP transceivers QSF 502 QSF 507 and QSF 506 respectively a 40Gb port can be broken out into four 10Gb ports called 4x10G mode Figure 7 Th...

Страница 41: ...over a 10 100 1000 Ethernet network Console Use the console port for local configuration of the GigaVUE TA Series TA200 Traffic Aggregator over a serial connection USB The USB port is not supported in software version 5 3 Table 8 GigaVUE TA Series TA200 Ports Contents 41 GigaVUE TA Series Hardware Installation Guide ...

Страница 42: ...h as PNL M341 which takes input from the GigaVUE TA Series TA200 and splits it to four independent 10Gb 25Gb output ports Refer to Breakout Panels Ports c11 c22or c11x1 c11x4 toc22x1 c22x4 When you use ports c11 c22 for port breakout there is an impact on the ports in the lower row of the GigaVUE TA Series TA200 In the following list ensure that the ports on the right do not have any configuration...

Страница 43: ... monitored When a component crosses a pre defined threshold the fan speed is adjusted dynamically in increments of approximately 15 An SNMP trap is sent when a component reaches the threshold for warning alert or critical temperature conditions Refer to Table 9 Component Temperature Thresholds and Actions for the temperatures at which the warning alert and critical traps are sent and any additiona...

Страница 44: ...ell as the intake temperature config show environment Card 1 TA200 C64 Intake temperature 29 C Exhaust temperature 28 C CPU temperature 36 C Switch CPU temperature 54 C The output of the following CLI command displays the transceiver temperature config show port params port list 3 1 c1 Parameter 3 1 c1 SFP type qsfp28 sr SFP Power 1 2 dBm 40 00 40 00 SFP Power 3 4 dBm 40 00 40 00 SFP Power 5 6 dBm...

Страница 45: ...LED on the front of the chassis SYS is as follows Off indicates no power Blinking GREEN indicates the node is booting or the system is in diagnostic mode Solid GREEN indicates normal operation Solid RED indicates the system has failed Port Status LEDs For each port there are four 4 port status LEDs on the front of the chassis At 40Gb and 100Gb speeds only the first LED operates as follows AMBER in...

Страница 46: ...l power LEDs on the rear of the chassis PWR1 and PWR2 are as follows GREEN indicates the PSU is operating normally AMBER indicates the input cord is unplugged the input power has been lost or there is a critical event that has caused the PSU to shutdown GigaVUE TA Series TA200 Notes and Rules Keep in mind the following notes and rules when using the GigaVUE TA Series TA200 GigaVUE TA Series TA200 ...

Страница 47: ...s the Advanced Features License AMI BIOS Images The GigaVUE TA Series TA200 has an AMI Basic Input Output System BIOS The BIOS image is packaged with the software image starting in software version 5 3 The BIOS contents are stored in flash memory allowing the BIOS to be upgraded There are two flash components a primary and a secondary The following CLI command displays the two flash components and...

Страница 48: ...for GigaVUE TA Series can be either in card mode or port mode GigaVUE TA10 allows card breakout mode whereas GigaVUE TA25 GigaVUE TA40 GigaVUE TA100 GigaVUE TA100 CXP GigaVUE TA200 allows port breakout mode Refer to Configure the Card Mode 40Gb 10Gb Support and Configure the Port Mode for further details Configure the Card Mode 40Gb 10Gb Support GigaVUE TA Series TA10 also enable the first four 40...

Страница 49: ...port and traffic settings for the system 2 To set the new card mode for GigaVUE TA Series TA10 card slot 1 mode 48x 56x 64x The settings for each available mode are summarized in Table 10 40Gb Port Settings by Card Mode on GigaVUE TA Series TA10 Card Mode Physical 40Gb Interface on GigaVUE TA Series TA10 q1 q2 q3 q4 48x default 40Gb q1 40Gb q2 40Gb q3 40Gb q4 56x 10Gb x49 x52 10Gb x53 x56 40Gb q3 ...

Страница 50: ...UE TA Series nodes Any of the 100Gb ports on the GigaVUE TA100 1 1 c1 to 1 1 c32 the first 32 ports on the GigaVUE TA200 1 1 c1 to 1 1 c32 the eight QSFP28 ports 1 1 c21 to 1 1 c28 on the GigaVUE TA100 CXP or the eight ports on GigaVUE TA25 1 1 c1 1 1 c8 can operate at 40Gb with QSFP SR transceivers A 40Gb port can be broken out into four 10Gb ports called subports In GigaVUE TA25 only the ports c...

Страница 51: ... subports is 8 2x 4 In 4x25G mode the subports can function as network tool or hybrid ports as well as GigaStream port members They cannot function as stack ports There are rules for configuring parent ports and subports For more information refer to the port command in the reference section of the GigaVUE OS CLI Reference Guide Once the port breakout mode has been configured refer to Breakout Pan...

Страница 52: ...hipped in If the carton was damaged please file a claim with the carrier who delivered it Remove the protective shipping covers and screws Save the protective shipping covers and replace the screws in the holes on the system so that they are easily saved in case you need to ship the system again Contents 52 GigaVUE TA Series Hardware Installation Guide ...

Страница 53: ...ling the GigaVUE TA Series Traffic Aggregation node NOTE Before rack mounting the GigaVUE TA Series TA Series please read the following safety precautions Install any stabilizers provided for the rack before installing the chassis Unsecured racks can tip over Install boxes in the rack from the bottom up with the heaviest boxes at the bottom Ensure adequate ventilation to the systems installed in t...

Страница 54: ...n node in a rack 1 Attach the orange rack ears to the front or rear of the unit rear mounting does not apply to GigaVUE TA Series TA200 and GigaVUE TA25 using the supplied screws As shown in Figure 10GigaVUE TA Series Traffic Aggregator Rack Ears in Front Mount Position the rack ears can be attached for a front mount or rear mount installation Select the installation that best fits the needs For e...

Страница 55: ...ls can be used for four point mounting on four post racks The keyhole rivets on the sides of each node can be used to adjust the fit of the node to the desired position or dimension on the rack Figure 11 GigaVUE TA Series Traffic Aggregator with Rail Mounting for Four Post Racks To mount the GigaVUE TA Series Traffic Aggregation node in a four post rack 1 Attach the orange rack ears to the front o...

Страница 56: ...in the provided rails on to the node The position of the rails can be adjusted to fit the dimensions of the rack by sliding over the rivets and placing them securely over the rivets once set in the desired position Contents 56 GigaVUE TA Series Hardware Installation Guide ...

Страница 57: ... Basic Connections and Configuration This chapter describes how to establish your first configuration session with the GigaVUE TA Series Traffic Aggregator and set the basic initial configuration options necessary to get you up and running Refer to the following sections for details Contents 57 GigaVUE TA Series Hardware Installation Guide ...

Страница 58: ... the chassis Refer to Figure 14Ground Screws GigaVUE TA Series TA10 Shown or Figure 15Ground Screws GigaVUE TA Series TA200 Shown Figure 14 Ground Screws GigaVUE TA Series TA10 Shown Figure 15 Ground Screws GigaVUE TA Series TA200 Shown Contents 58 GigaVUE TA Series Hardware Installation Guide ...

Страница 59: ...skin contact The strap can be connected to one of the following Captive installation screws on chassis Any unpainted surface on the chassis Avoid contact between the cards and clothing The wrist strap protects only the chassis from ESD voltages on the body ESD voltages on clothing can still cause damage Connecting Power to the GigaVUE TA Series TA Series The procedure below describes how to supply...

Страница 60: ...Figure 16 Connecting AC Power Figure 17 Connecting AC Power on a GigaVUE TA Series TA100 Contents 60 GigaVUE TA Series Hardware Installation Guide ...

Страница 61: ...OTE The GigaVUE TA Series does not have power switches once you connect the system to power it automatically powers on Refer to Connecting Serial Console and Mgmt Ports for information on how to connect to the GigaVUE TA Series TA Series command line interface CLI Connecting 48V DC Power Supplies The GigaVUE TA Series Traffic Aggregator is available with two DC power supplies instead of the standa...

Страница 62: ...traight blade screwdriver Connect the 48V source wire to the 48V blue terminal using a straight blade screwdriver IMPORTANT The leads to the DC power supply modules on the GigaVUE TA Series TA Series node should attach from the side of the chassis away from the terminal block Run the wires to avoid obstructing airflow for the adjacent fans 4 Repeat Step 1 through Step 3 for the other power supply ...

Страница 63: ...3 When fan is fully inserted it locks in place Connecting Serial Console and Mgmt Ports To make basic connections serial console and Mgmt ports 1 Locate the DB9 to RJ45 serial cable provided with the GigaVUE TA Series TA Series node This cable is called a console cable NOTE This cable is Cisco compatible Refer to B Console Port Signaling and Cabling on page 99 for pinout details 2 Connect the RJ45...

Страница 64: ...he password through the jump start script Refer to Access the Command Line Interface over the console Port Once you have used the console port to configure the Mgmt port s network properties you can configure the GigaVUE TA Series TA Series node remotely using the Mgmt port s network connection NOTE The same commands are available in the command line interface regardless of how you connect Access ...

Страница 65: ...ging the console Port s speed to 9600 bps using the procedure in Changing the Console Port s Speed and reconnecting NOTE The GigaVUE TA Series TA100 GigaVUE TA Series TA100 CXP GigaVUE TA Series TA200 and GigaVUE TA25 support only a fixed serial baud rate of 115 200bps Figure 22 Setting COM Port Properties for the Console Connection 5 Start the terminal connection You may need to press Enter a few...

Страница 66: ...TA Series TA10 and GigaVUE TA Series TA40 with the serial baudrate 9600 115200 command Keep in mind the following points when changing the console port s speed After changing the console port s speed you must save the active configuration and reload the system for the change to take effect After setting the console port to 9600bps the u boot output will appear correctly on the connected serial con...

Страница 67: ...e chassis in SNMP traps Management Port Network Settings Use either DHCP or specify a static IP address and netmask If you do not use DHCP you are prompted to configure the following additional options Default Gateway Supply the IP address of the default gateway for the node DNS Server Supply the IP address of the DNS server for the node Note that a valid DNS server is required for successful use ...

Страница 68: ...g settings If clustering is enabled you will not be prompted for a box ID in the next step Refer to the GigaVUE OS CLI Reference Guide for information on setting up a cluster NOTE Connecting a Traffic Aggregator to a cluster requires a license Box ID for the Node Supply a numerical box ID for the node This box ID is used to identify network tool ports in the node the format is box ID slot ID port ...

Страница 69: ...UE TA Series 100 CXP and GigaVUE TA25 have all ports enabled Additional ports are available through licenses for the following GigaVUE TA Series products GigaVUE TA Series TA10A GigaVUE TA Series TA100 GigaVUE TA Series TA200 GigaVUE TA25A Contact your Sales representative for port licenses Refer to Contacting Sales on page 107 GigaVUE TA Series TA10A The GigaVUE TA Series TA10 has all forty eight...

Страница 70: ... enable an additional 32 ports to expand from 32 ports to 64 ports GigaVUE TA25A The GigaVUE TA25 has 25Gb 10Gb 1Gb and eight 100Gb 40Gb ports enabled It does not require a port license A twenty four 24 port GigaVUE TA25 version called the GigaVUE TA25A is available with only the first 24 25Gb 10Gb 1Gb ports active The GigaVUE TA25A product code is 132 00FK and the GigaVUE TA25 product code is 132...

Страница 71: ...hen switch to Configure mode The GigaVUE TA Series TA Series node provides three command entry modes each with increasingly powerful rights Standard Enable and Configure The jump start script is only available in Configure mode a Type en Enter to switch to Enable mode The system prompt changes from hostname to hostname b Type config t Enter to switch to Config mode The system prompt changes from h...

Страница 72: ...VUE OS can operate in one of three modes each with its own set of available commands Standard Enable and Configure When you first launch the CLI you start in Standard mode with access to a limited amount of commands used to review system status As you move from Standard mode to Enable mode to Configure mode both the power and the number of commands available increase as summarized in Figure 23Giga...

Страница 73: ...dentify available commands and enter them quickly Technique Description Context Sensitive Help The symbol is the key to receiving help wherever you are in the CLI Type the by itself to see a list of all available commands Word Help Type a partial word with a mark immediately following the Contents 73 GigaVUE TA Series Hardware Installation Guide ...

Страница 74: ...ter Partial Command Entry For all GigaVUE TA Series commands and arguments you only need to enter enough characters to distinguish the command from all other available commands So for example you do not have to enter the full command username there is only one command starting with the letter u so you only have to enter u Command Completion If you have partially typed a command you can press Tab a...

Страница 75: ...s do accept spaces provided the input is made inside quotation marks Config Mode Syntax When using the GigaVUE TA Series CLI the config part of the command is implied whenever you are working in Configure mode The system prompt helps you remember this by including the word config in parentheses For example config So instead of entering config map to connect a network port to a tool port you just e...

Страница 76: ...scription aaa Configure authentication authorization and accounting settings banner Set a system login banner bond Configure bonded interface settings boot Configure system boot parameters card Configure a card On TA Series nodes use the card command to enable additional ports on GigaVUE TA Series nodes chassis Configure the chassis clear Reset statistics or clear caches cli Configure CLI shell op...

Страница 77: ...s in the system prompt and in SNMP traps ib pathway Reserved for future use image Manage system software images interface Configure network interfaces ip Configure IP settings for the eth0 Mgmt port ipv6 Configure IPv6 settings for the eth0 Mgmt port job Configure scheduled jobs ldap Configure LDAP server settings for authentication license Activate features using license keys On GigaVUE TA Series...

Страница 78: ...mber of seconds snmp server Configure SNMP settings including the local SNMP server notification events and notification destinations spine link Configures spine links in a cluster with a leaf and spine architecture ssh Enable and disable SSH access as well as manage settings stack link Configure a stack link between two nodes in a cluster Stack links are used to carry data traffic between nodes i...

Страница 79: ...ing the Web Server Save your changes Refer to Saving Changes Enter the Configure Command Line Mode Keep in mind that the GigaVUE OS have three different command modes for the CLI Standard Enable and Configure The commands described in the sections below are all only available in Configure mode Switch to configure mode as follows Command Notes enable You only need to supply enough of each command t...

Страница 80: ... you think it is The GigaVUE TA Series nodes also include default RSA v1 v2 and DSAv2 encrypted public host keys SSH2 supports both RSA and DSA encryption algorithms The first time you connect to the GigaVUE TA Series node with an SSH2 client the client will warn you that the host keys are not in your local cache and show you the actual host key presented by the node Your client will most likely g...

Страница 81: ...asswords must meet the following standards Include 8 30 characters Include at least one numeral Include at least one capital letter Include at least one special character for example or ASCII 0x21 0x2F 0x3A 0x40 0x5B 0x5F 0x7B 0x7E Enter a new password that meets the standards and confirm the password Setting Up Some Basic Accounts 1 The TA Series node has a local account database that can optiona...

Страница 82: ...username commands create a new admin user and a new operator user Command Comments config username psandoval password Nine9 Eight8 config username psandoval roles add admin Creates a new account named psandoval with a password and grants it admin privileges config username bcrawford password Seven7 Six6 Creates a new account named bcrawford with a password New users are automatically created with ...

Страница 83: ...rver address Performing One Time NTP Server Synchronization Persistent NTP Synchronization Add server using ntp server command Enable use of ntp with ntp enable command Using NTP Time Server for System Clock Synchronization Setting Time Manually The easiest way to set the GigaVUE TA Series node s time is manually with the clock set command For example config clock set 05 18 38 2011 05 24 NOTE Even...

Страница 84: ...r and synchronizes to its time 4 NTP reports times in UTC Because of this It is a good idea to specify the GigaVUE TA Series node s timezone so that UTC can be converted to the local timezone You specify the timezone in terms of the offset from UTC either plus or minus For example to set the timezone for a GigaVUE TA Series node in the United States for Pacific Standard Timezone you would use the ...

Страница 85: ... to the HTTPS port with the web http redirect command 1 Open a supported browser For the list of the latest browser support available refer to the GigaVUE OS CLI Reference Guide for the release you have installed on the GigaVUE TA Series node 2 Enter one of the following URLs https GigaVUE TA Series Node IP Address http GigaVUE TA Series Node IP Address 3 The first time you connect to H VUE your b...

Страница 86: ...Click OK on the Temporary Internet Files and History Settings dialog 6 Click OK on the Internet Options dialog Configuring Automatic Email Notifications The GigaVUE TA Series nodes provide powerful email notification capabilities automatically sending emails to specified addresses when any of a wide variety of events take place on the system Gigamon strongly recommends that you configure this feat...

Страница 87: ...w that the settings are configured let the system send emails Set up who to send them to and when to send them Use email notify recipient to configure the destinations for event notification emails Multiple destinations can be specified by separating by commas with no spaces config email notify recipient cday mycompany com mfelton mycompany com The email notify event command lets you configure whi...

Страница 88: ...h the no email autosupport event command config email autosupport enable That s it Emails will now be sent automatically to the configured addresses when any of the selected events take place There are many other options for fine tuning automatic email settings including how to handle dead letters emails that did not reach their recipient how the email address of the GigaVUE TA Series should appea...

Страница 89: ... show configuration and look for the Running database entry Connecting Ports on GigaVUE TA Series TA Series This chapter provides information on the transceivers supported for use with the GigaVUE TA Series TA Series Refer to the following sections for details Transceiver Rules and Notes Keep in mind the following rules and notes when you connect and use GigaVUE TA Series nodes with transceivers A...

Страница 90: ...k links RX only BiDi optics must be used due to the way traffic is multiplexed over the fiber pair in 40Gb BiDi technology When deploying over inline 40Gb BiDi links Full Duplex BiDi optics must be used When connecting two GigaVUE TA Series nodes through a cascade connection Full Duplex BiDi optics must be used for the tool port The network port may be either Full Duplex or RX only BiDi optics Whe...

Страница 91: ... Use with SR4 Transceivers MTP APC 12 Position Fiber Cable for Use with QSFP PLR4 Transceivers MPO MTP 24 Position Fiber Cable for Use with SR10 Transceivers For details about the supported transceiver cable type and connectivity specifications refer to GigaVUE OS Compatibility and Interoperability Matrix For details about how to cable GigaVUE TA Series nodes refer to GigaVUE OS Cabling Quick Refe...

Страница 92: ...tails for MTP APC 12 position fiber cable for use with 40Gb QSFP PLR4 transceivers on the GigaVUE TA Series TA10 GigaVUE TA Series TA40 or GigaVUE TA Series TA100 node Figure 28 MTP APC Cable MPO MTP 24 Position Fiber Cable for Use with SR10 Transceivers This is a female to female Ultra Polished Connector UPC of cable type B Figure 29MPO MTP 24 Position Fiber Cable provides cabling details for MPO...

Страница 93: ...al specifications for the GigaVUE TA Series Traffic Aggregation nodes GigaVUE TA Series TA10 GigaVUE TA Series TA40 GigaVUE TA Series TA100 GigaVUE TA Series TA100 CXP GigaVUE TA Series TA200 and GigaVUE TA25 Compliance for safety emissions and immunity are also provided Refer to the following topics for details Contents 93 GigaVUE TA Series Hardware Installation Guide ...

Страница 94: ... ears 17 32in 44cm without ears Metal to Metal 18 12in 46 0cm Including latches19 25in 48 89cm 22 99lb 10 43kg GigaVUE TA Series TA100 CXP with mounting brackets 1 74in 1RU 4 42cm 19 00in 48 26cm with ears 17 32in 44cm without ears Metal to Metal 18 12in 46 0cm Including latches19 25in 48 89cm 24 89lb 11 29kg GigaVUE TA Series TA200 with two power supplies 3 48in 2RU 8 84cm 19 00in 48 26cm with ea...

Страница 95: ...ower Consumption Heat Output 280 Watts 954 8 BTU hr AC Power Supply Modules Min Max Voltage 100V 127V AC 200V 240V AC 50 60HzMax PSM Input Current 5 8A 100V 2 9A 200V DC Power Supply Modules Min Max Voltage 40 5V to 60V DCMax PSM Input Current 24A 40 5V Table 12 Power Requirements for GigaVUE TA Series TA40 Power Configurations 1 1 Power 2 Power Supply Modules Max Power Consumption Heat Output 550...

Страница 96: ... PSM Input Current Steady State 20A 48V DC Fan Tray Specification for GigaVUE TA Series TA100 and TA100 CXP The GigaVUE TA Series TA100 and GigaVUE TA Series TA100 CXP use a fan tray for cooling GigaVUE TA Series TA100 and TA100 CXP Fan Tray Specifications summarizes the characteristics of the fan tray Rated Voltage 12V DC Input Power Maximum 18W Maximum Speed 19000 RPM Type Dual axial flow fans G...

Страница 97: ...eries TA40 summarizes the environmental specifications for the GigaVUE TA Series Traffic Aggregation nodes GigaVUE TA Series TA10 and GigaVUE TA Series TA40 Environmental Specifications summarizes the environmental specifications for the GigaVUE TA Series TA100 GigaVUE TA Series TA100 CXP GigaVUE TA Series TA200 and GigaVUE TA25 Specification Value Operating Temperature 32ºF to 104ºF 0ºC to 40ºC O...

Страница 98: ...ab 1000BASE T IEEE 802 3z 1000BASE X IEEE 802 3ae 10000BASE X IEEE 802 3ba RFC 783 TFTP RFC 791 IP RFC 793 TCP RFC 826 ARP RFC 768 UDP RFC 792 ICMP SNMP v1 v2c RFC 2131 DHCP client RFC 1492 TACACS and support for IPv4 and IPv6 Compliance This section provides compliance information for GigaVUE TA Series Traffic Aggregation nodes GigaVUE TA Series TA Series Safety GigaVUE TA Series Traffic Aggregat...

Страница 99: ... TA100 and GigaVUE TA Series TA200 Immunity GigaVUE TA Series Traffic Aggregation nodes are compliant with the following immunity regulations ETSI EN300 386 V1 6 1 2012 not applicable on GigaVUE TA Series TA200 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 EN61000 3 2 EN61000 3 3 Environmental GigaVUE TA Series Traffic Aggregation nodes are compliant with the...

Страница 100: ...on available for GigaVUE TA Series TA10 and GigaVUE TA Series TA40 Refer to UC APL Compliance in the GigaVUE OS CLI User s Guide Common Criteria option available for GigaVUE TA Series TA10 and GigaVUE TA Series TA40 Refer to Common Criteria in the GigaVUE OS CLI User s Guide BSMI RoHS The RoHS label for Taiwan BSMI for GigaVUE TA Series TA200 is as follows VCCI The Class A Information Technology E...

Страница 101: ...a domestic environment radio disturbance may occur in which case the user may be required to take corrective action Warranty Gigamon offers a range of premium support and extended services For details regarding warranty visit https www gigamon com support and services warranty Regulatory Labels This section provides regulatory labels for GigaVUE TA Series TA Series nodes Contents 101 GigaVUE TA Se...

Страница 102: ...GigaVUE TA Series TA10 GigaVUE TA Series TA40 Contents 102 GigaVUE TA Series Hardware Installation Guide ...

Страница 103: ...GigaVUE TA Series TA100 GigaVUE TA Series TA100 CXP Contents 103 GigaVUE TA Series Hardware Installation Guide ...

Страница 104: ...GigaVUE TA Series TA200 GigaVUE TA25 Contents 104 GigaVUE TA Series Hardware Installation Guide ...

Страница 105: ...X1 X48 40G QSFP Q1 Q4 GigaVUE TA Series TA10 equipment or subassembly are suitable for connection to intrabuilding or unexposed wiring or cabling only The intra building port s of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring These interfaces are designed for use as intra building interfaces only Type 2 or Type 4 ports as descri...

Страница 106: ... to interfaces that connect to the OSP or its wiring These interfaces are designed for use as intra building interfaces only Type 2 or Type 4 ports as described in GR 1089 CORE Issue 6 and require isolation from the exposed OSP cabling The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring Intrabuilding or Intra connection fo...

Страница 107: ...hall be installed and connected to the CBN Communication Equipment Grounding The GigaVUE TA Series TA10 GigaVUE TA Series TA40 GigaVUE TA Series TA100 or GigaVUE TA Series TA200 is suitable for connection to the Central Office and CPE Bonding of Battery Return BR Input Terminals The battery returns of the GigaVUE TA Series TA10 GigaVUE TA Series TA40 GigaVUE TA Series TA100 or GigaVUE TA Series TA...

Страница 108: ...bonded or grounded shall be removed from threads and other contact surfaces to assure electrical continuity i GigaVUE TA Series TA10 GigaVUE TA Series TA40 GigaVUE TA Series TA100 or GigaVUE TA Series TA200 utilizes a Spade width 0 32in 81cm with a Standard Wire 14 16 AWG that utilizes 5in lbs of torque to secure it to the frame and EUT Only listed two hole compression type connectors shall be use...

Страница 109: ...e CAUTION Remove all power sources before servicing TO COMPLETELY REMOVE POWER FROM THE UNIT FIRST TURN OFF THE POWER SWITCH AND REMOVE BOTH POWER CABLES Contents 109 GigaVUE TA Series Hardware Installation Guide ...

Страница 110: ...ucts GigaVUE TA Series 5 12 Hardware and Software Guides DID YOU KNOW If you keep all PDFs for a release in common folder you can easily search across the doc set by opening one of the files in Acrobat and choosing Edit Advanced Search from the menu This opens an interface that allows you to select a directory and search across all PDFs in a folder Hardware how to unpack assemble rack mount connec...

Страница 111: ... Suite for AnyCloud Configuration Guide how to deploy the GigaVUE Cloud Suite solution in any cloud platform GigaVUE Cloud Suite for AWS Configuration Guide GigaVUE Cloud Suite for AWS Quick Start Guide quick view of AWS deployment GigaVUE Cloud Suite for AWS SecretRegions Configuration Guide GigaVUE Cloud Suite for Azure Configuration Guide GigaVUE Cloud Suite for Kubernetes Configuration Guide G...

Страница 112: ...load Software and Release Notes from My Gigamon In Product Help GigaVUE FM Online Help how to install deploy and operate GigaVUE FM GigaVUE OS H VUE Online Help provides links the online documentation How to Download Software and Release Notes from My Gigamon Registered Customers can download software and corresponding Release Notes documents from the Software Release Notes page on to My Gigamon U...

Страница 113: ...orm into your email complete it as able and send We will respond as soon as possible Documentation Feedback Form About You Your Name Your Role Your Company For Online Topics Online doc link URL for where the issue is Topic Heading if it s a long topic please provide the heading of the section where the issue is For PDF Topics Document Title shown on the cover page or in page header Product Version...

Страница 114: ...information on purchasing 24x7 Premium Support Premium Support entitles you to round the clock phone support with a dedicated Support Engineer every day of the week The Gigamon Community The Gigamon Community is a technical site where Gigamon users partners security and network professionals and Gigamon employees come together to share knowledge and expertise ask questions build their network and ...

Страница 115: ... Customers only Open support tickets Customers only Download the latest product updates and documentation Customers only The Gigamon Community is a great way to get answers fast learn from experts and collaborate directly with other members around your areas of interest Register today at community gigamon com Questions Contact our Community team at community gigamon com Additional Sources of Infor...

Отзывы: