Slim Relay

 

G3RV

SSR for Maintenance

Model Number Legend

1. Output voltage specifications

D: DC 

Output

2: AC 

Output

2. Rated Current

02: 

AC Output 2A

03: 

DC Output 3A

3. Terminals

S: Plug-In

4. Zero cross function

Blank: with Zero cross function
L : 

without Zero corss function

List of Models

*

different by ambient temperature.
Please refer to 4 pages of characteristic data “ 

 Load current derating curves” for the details.

1

2

3

4

G

3

RV-

@

 

@ @ @

Isolation

Movement 

indication

Rated input 

voltage 

(Socket)

Output 

(SSR)

Zero cross 

function

Rated 

output 

load

*

Model Number

Replacement for

Phototriac

Yes (Green)

DC12V

AC

Yes

2A at 100 
to 240VAC

G3RV-202S DC12

G3RV-SL700/500-A DC12

DC24V

G3RV-202S DC24

G3RV-SL700/500-A DC24

AC/DC24V

G3RV-SL700/500-A AC/DC24

AC/DC48V

G3RV-SL700/500-A AC/DC48

AC110V

G3RV-202S DC48

G3RV-SL700/500-A AC110

AC230V

G3RV-SL700/500-A AC230

DC12V

No

G3RV-202SL DC12

G3RV-SL700/500-AL DC12

DC24V

G3RV-202SL DC24

G3RV-SL700/500-AL DC12

AC/DC24V

G3RV-SL700/500-AL AC/DC24

AC/DC48V

G3RV-SL700/500-AL AC/DC48

AC110V

G3RV-202SL DC48

G3RV-SL700/500-AL AC110

AC230V

G3RV-SL700/500-AL AC230

Photocoupler

DC12V

DC

---

3A at 5 to 
24 VDC

G3RV-D03SL DC12

G3RV-SL700/500-D DC12

DC24V

G3RV-D03SL DC24

G3RV-SL700/500-D DC24

AC/DC24V

G3RV-SL700/500-D AC/DC24

AC/DC48V

G3RV-D03SL DC48

G3RV-SL700/500-D AC/DC48

AC110V

G3RV-SL700/500-D AC110

AC230V

G3RV-SL700/500-D AC230

Содержание G3RV

Страница 1: ...G3RV SL Classification Enclosure rating Input voltage Type of connection Contact form SPST Plug in terminals General purpose Unsealed AC DC Screw terminals G3RV SL700 Push in terminals G3RV SL500 Inp...

Страница 2: ...VDC 12 mA 21 6V 24 VAC DC 20 mA 21 mA 11 mA 21 6V 48 VAC DC 10 mA 11 mA 6 mA 43 2V 110 VAC 7 5 mA 8 2 mA 99V 230 VAC 7 3 mA 8 6 mA 207V Rated voltage Rated current Must operate voltage Must release vo...

Страница 3: ...icing or condensation Operating 30 55 C with no icing or condensation Ambient humidity 45 85 RH Weight Approx 38 g Pollution degree 2 Degree of protection according to IEC 60529 IP20 Rated Impulse Wit...

Страница 4: ...e Current Non repetitive Non repetitive Keep the inrush current to half the rated value if it occurs repetitively The values shown by the solid line are for non repetitive inrush currents Mounting Dis...

Страница 5: ...tion Connection P2RVC 8 O F PLC Output Interface for 8x G2RV SL700 G3RV SL700 series PNP type Ribbon cable connector 10 Pole IEC603 1 Input Rated voltage 30 VAC VDC max Current capacity 0 5 A per chan...

Страница 6: ...Green DC12V AC Yes 2A at 100 to 240VAC G3RV 202S DC12 G3RV SL700 500 A DC12 DC24V G3RV 202S DC24 G3RV SL700 500 A DC24 AC DC24V G3RV SL700 500 A AC DC24 AC DC48V G3RV SL700 500 A AC DC48 AC110V G3RV...

Страница 7: ...minimum order Red R Blue S Black B P2RVM 030 3 60 pcs box minimum order P2RVM 040 4 60 pcs box minimum order P2RVM 100 10 20 pcs box minimum order P2RVM 200 20 20 pcs box minimum order Max current EN...

Страница 8: ...n P2RV S 50 plates Provides isolation between adjacent relays to achieve 400 V isolation Five M2 5 6 6 2 max 99 2 7 1 88 9 26 1 47 2 70 9 83 106 7 max 92 7 max 35 Input circuit 24 V DC Terminal Arrang...

Страница 9: ...ew Other Input Voltage Terminal Arrangement Internal Connections Top View 12 V DC Terminal Arrangement Internal Connections Top View 6 2 max 99 2 88 9 7 1 24 6 46 69 8 82 9 106 7 max 97 4 max 35 G3RV...

Страница 10: ...tool Applicable Wires Applicable Wire Sizes G3RV SL700 Series Box clamp technology G3RV SL500 Series Push in technology Tightening torque G3RV SL700 Series 0 4Nm 2 5 dia 3 0 mm max Cannot be used Fla...

Страница 11: ...conductor into the connection hole No other tools are required Note In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire Screwdriver should be re...

Страница 12: ...e to connect cables properly if the screwdriver is inserted incorrectly General Precautions Do not use the product if it has been dropped on the ground Dropping the product may adversely affect perfor...

Страница 13: ...Induction will be generated and cause malfunction or damages Be sure to conduct wiring with the power supply turned OFF Touching the terminals when they are charged may occationally result in minor el...

Страница 14: ...ducts in the customer s application or use of the product Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it will be used Know an...

Отзывы: