manualshive.com logo in svg
background image

Read and Understand This Catalog 

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or 
comments. 
 

Warranty and Limitations of Liability 

 
WARRANTY 

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) 
from date of sale by OMRON. 
 
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR 
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.    ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS 
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.    OMRON DISCLAIMS ALL OTHER 
WARRANTIES, EXPRESS OR IMPLIED. 

 

LIMITATIONS OF LIABILITY 

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS 
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT 
LIABILITY. 
 
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. 
 
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS 
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT 
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 

 

 

Application Considerations 

 
SUITABILITY FOR USE 

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's 
application or use of the products.   
     
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the 
products.    This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, 
machine, system, or other application or use. 
 
The following are some examples of applications for which particular attention must be given.    This is not intended to be an exhaustive list of all possible 
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: 
 

  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. 

 

  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, 

safety equipment, and installations subject to separate industry or government regulations. 

 

  Systems, machines, and equipment that could present a risk to life or property.     

 
Please know and observe all prohibitions of use applicable to the products. 
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 

 

PROGRAMMABLE PRODUCTS 

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 

 

 

Disclaimers 

 
CHANGE IN SPECIFICATIONS 

Product specifications and accessories may be changed at any time based on improvements and other reasons. 
 
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.   
However, some specifications of the products may be changed without any notice.    When in doubt, special model numbers may be assigned to fix or 
establish key specifications for your application on your request.    Please consult with your OMRON representative at any time to confirm actual 
specifications of purchased products. 
 

DIMENSIONS AND WEIGHTS 

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. 

 

PERFORMANCE DATA 

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the 

result of OMRON’s test conditions, and the users must correlate it to actual application requirements. 

Actual performance is subject to the OMRON 

Warranty and Limitations of Liability. 

 

ERRORS AND OMISSIONS 

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, 
typographical, or proofreading errors, or omissions. 

 

 

 

2012.8 

In the interest of product improvement, specifications are subject to change without notice. 

OMRON Corporation 

Industrial Automation Company 

 

http://www.ia.omron.com/ 

(c)Copyright OMRON Corporation 2012 All Right Reserved. 

Содержание G3PA

Страница 1: ...nd VDE reinforced insulation Refer to Safety Precautions for All Solid State Relays For the most recent information on models that have been certified for safety standards refer to your OMRON website...

Страница 2: ...430B VD 2 30 A at 200 to 480 VAC G3PA 450B VD 2 50 A at 200 to 480 VAC Name Carry current Load voltage range Model Applicable SSR VDE certification Power Device Cartridge 10 A 19 to 264 VAC G32A A10 V...

Страница 3: ...1 VDC min G3PA 430B VD G3PA 420B VD 2 G3PA 430B VD 2 G3PA 450B VD 2 Model Rated load voltage Load voltage range Load current Inrush current VDRM reference value G3PA 210B L VD 24 to 240 VAC 50 60 Hz...

Страница 4: ...s 1 800 A2 s 1 800 A2 s Insulation resistance 100 M min at 500 VDC Dielectric strength 4 000 VAC 50 60 Hz for 1 min Vibration resistance Destruction 10 to 55 to 10 Hz 0 375 mm single amplitude Mounted...

Страница 5: ...the temperature indicator will not turn red Be sure to turn OFF the power supply when replacing the Cartridge Supplying power with the Cartridge removed may result in malfunction To remove or replace...

Страница 6: ...he letters on the cartridge and those on the G3PA are in the same direction and side A and side B are even 4 Attach the terminal cover 5 Switch on the power and check the G3PA to be sure it works prop...

Страница 7: ...ert the linking terminal securely into the center of the screw and tighten the screw SSR G32A Unit SSR G32A Unit The cover will not fit if the terminal protrudes 1 When SSR are close mounted loosen th...

Страница 8: ...0 20 30 60 40 25 20 80 Panel Ground Ambient temperature C Ambient temperature C Ambient temperature C Load current A Load current A Load current A Vertical Mounting G3PA 240B L VD G3PA 260B L VD G3PA...

Страница 9: ...Input impedance k Input impedance k 40 60 80 100 20 0 20 30 60 40 42 20 3 5 11 28 15 11 14 18 20 10 5 5 5 10 7 Panel Ground Horizontal Mounting Ambient temperature C Ambient temperature C Ambient tem...

Страница 10: ...430B VD 2 Load current A Ambient temperature C Load current A G3PA 420B VD G3PA 420B VD 2 DIN track Panel Ground Close Mounting Up to Three Ambient temperature C Ambient temperature C Ambient temperat...

Страница 11: ...e rated value if it occurs repetitively G3PA 210B L VD G3PA 220B L VD G3PA 420B VD G3PA 420B VD 2 G3PA 240B L VD 260B L VD G3PA 430B VD G3PA 430B VD 2 G3PA 450B VD 2 Inrush current A Peak Energized ti...

Страница 12: ...ircuit Two 4 5 dia or M4 holes 4 6 dia Two M4 100 max G3PA 220B L VD Mounting Holes Without Terminal Cover With Terminal Cover Linking terminal B1 Two M3 5 Linking terminal B2 4 6 x 5 6 elliptical hol...

Страница 13: ...5 4 6 dia 37 max 4 5 x 5 6 elliptic hole 100 max G3PA 420B VD G3PA 420B VD 2 Mounting Holes Terminal Arrangement Internal Connections Trigger circuit Input circuit 100 max Linking terminal B2 Linking...

Страница 14: ...age according to EN55011 The G3PA VD complies with EN55011 standards when a capacitor is connected to the load power supply as shown in the following circuit diagram Recommended Capacitor 1 F 250 VAC...

Страница 15: ...rrents of 20 A 0 31 x 10 3 1 Thus 4 fans would be required Size of fans 92 mm2 Air volume 0 7 m3 min Ambient temperature of control panel 30 C If there are other instruments that generate heat in the...

Страница 16: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...

Отзывы: