Basic Knowledge For Macro Customize Functions
202
Vision System FH/FZ5 Series
User’s Manual (Z340)
Key Points for Test Measurement and Adjustment (Unit Macro)
To increase the speed and precision of measurement, you can adjust the parameters by performing and
checking the results of test measurements.
The following content is displayed in the "Detail result" area as text.
The image specified in the sub image in image display setting is displayed in the image display area.
Key Points for Adjustment
Select the adjustment method referring to the following points.
An error message appears on the console
Nothing happens when [DEL], [BS], [Enter], etc., is clicked
Want to include a line feed code in a string
The "Positions" display is not as desired
Data acquisition sometimes fails during measurement
Check the measurement results that can be displayed and output in "Measurement Results For Which Output
is Possible".
Reference:
External Reference Table (Unit Macro) (p.203)
Displayed items
Description
Judge
Judgement result
Sub image.
Explanation of image to be displayed
0
Measurement image
Parameter to be adjusted
Troubleshooting
-
Refer to the error messages list.
Reference:
X
"Appendixes About Macro Functions List of Macro Error Messages" in the
"Vision System FH/FZ5 Series User's Manual (Z340)"
Parameter to be adjusted
Troubleshooting
-
Nothing happens while the focus is not on the code window (key entry cursor is not
displayed). Click the position you want to operate, and then click the button.
Parameter to be adjusted
Troubleshooting
Macro code
Add (+) CR
→
Chr$(13) LF
→
Chr$(10) to the string.
Parameter to be adjusted
Troubleshooting
Macro code
When "Positions" is OFF, the display processing written in "*MEASUREDISPT" and
"*MEASUREDISPG" is executed. When "Positions" is ON, only what is written in
"*MEASUREDISPG" is displayed.
Parameter to be adjusted
Troubleshooting
Macro code
Data may be stolen by the applicable communication processing unless the communication
processing is stopped using the SetPollingState function.
(Example) Receive data without TCP procedure
Write the processing in the following sequence.
• SetPollingState "TcpNormal", false
• Data receive processing
• SetPollingState "TcpNormal", true
Содержание fh-1 series
Страница 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Страница 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Страница 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Страница 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Страница 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Страница 132: ...WWW NNC IR Useful Functions for Operation 130 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Страница 172: ...WWW NNC IR Saving Scene Groups in External Memory 170 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Страница 254: ...WWW NNC IR Basic Knowledge For Macro Customize Functions 252 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Страница 650: ...WWW NNC IR Macro Reference 648 Vision System FH FZ5 Series User s Manual Z340 Related Items None...
Страница 881: ...WWW NNC IR...