Section 1 Description
B-6
Type
Item
F3SN-B
P25
F3SN-B
P40
F3SN-B
P70
Ambient light intensity
Incandescent lamp : 3,000 Ix max. (light intensity on the receiver surface)
Sunlight
: 10,000 Ix max. (light intensity on the receiver surface)
Insulation resistance
20 M
Ω
min. (at 500 VDC)
Dielectric strength voltage
1000 VAC 50/60 Hz 1 minute
Degree of protection
IP65(IEC60529)
Vibration resistance
Normal operation : 10 to 55 Hz, double amplitude 0.7 mm, X, Y and Z directions 20 sweeps
Shock resistance
Normal operation : 100 m/s
2
, X,Y and Z directions 1000 times
Cable (optional) *3
UL20276 (flame-resistant:), 8 cores (0.3 mm
2
x 4pairs), external diameter 6.6 mm,
with braided wire shield, allowable bending radius: R36 mm
Materials
Case
:
Aluminum
Cap
: Zinc die-cast
Optical cover
: PMMA (acrylic resin)
Cable
: Oil-proof PVC
Weight *Packaged
Calculate with the following equation:
Weight of light curtain with protective height of 180 mm to 738 mm (g)
= (Protective 100) x 2 + 1300)
Weight of light curtain with protective height of 747 mm to 1402 mm (g)
= (Protective 100) x 2 + 1700)
Weight of light curtain with protective height of 1417 mm to 1822 mm (g)
= (Protective 100) x 2 + 2100)
Accessories
Test rod *4, Instruction manual, Mounting brackets (top and bottom),
Mounting brackets (intermediate)*5, Error mode label
Applicable standard
IEC61496-1, EN61496-1 TYPE 2 ESPE (Electro-Sensitive Protective Equipment)
IEC61496-2 TYPE 2 AOPD (Active Opto-electronic Protective Devices)
*1.
Please note that the operation may differ from conventional ON/OFF switching because of the safety circuit.
*2. Flashing after a lapse of 30000 hours as an indicator of preventive maintenance.
*3.
When extending the cable(100 m max), be sure to use a cable with at least same performance. Be sure to
route the F3SN-B cable separated from high-potential power lines or through an exclusive conduit.
*4.
Test rod is not supplied with the F3SN-B
P70.
*5.
The intermediate mounting bracket is supplied with the following types:
Types which have the total length of the light curtain from 640 mm to 1280 mm: 1 set for each of emitter and
receiver
Types which have the total length of the light curtain over 1280 mm: 2 sets for each of emitter and receiver
1-3-2 Response time
The response time of OSSD outputs are as follows:
Protective
height(mm)
No. of beams
Response time
(ON to OFF)
Response time
(OFF to ON)
217 to 772
13 to 50
10.0
40
787 to 1297
51 to 85
12.5
50
F3SN-B
P25
1312 to 1822
86 to 120
15.0
60
217 to 757
7 to 25
10.0
40
787 to 1297
26 to 43
12.5
50
F3SN-B
P25
1327 to 1807
44 to 60
15.0
60
277 to 757
5 to 13
10.0
40
817 to 1297
14 to 22
12.5
50
F3SN-B
P25
1357 to 1777
23 to 30
15.0
60
Response time of F3SP-B1P is 10 ms, operation time is 100 ms.
[Note]:
If the controller is included in the set, calculate safety distance by adding the controller response
time to the F3SN response time.
Содержание F3SN-B P Series
Страница 1: ...TYPE 2 PNP Output ype F3SN B P Series Safety Light Curtain Instruction Manual ENGLISH Cat No SCEE 717...
Страница 10: ...A 3 1 2 4 b b OFF 300ms 1 b 9V Vs 2 4 1 2 5 2 1 mm...
Страница 14: ...A 7 2 1 2 1 1 F3SN B F3SN B...
Страница 17: ...A 10 2 1 3 D 0 2 3m 0 27m 3m L 2 tan10 L 0 087 m 2 1 4 F3SN B 2 F3SN B L D D L D 10 10...
Страница 18: ...A 11 0 2 3m 0 54m 3m L tan10 L 0 18 m L D D 10 10...
Страница 21: ...A 14 2 3 2 3 1 F3SN B R36 mm 52mm R 3 6 R 3 6 R 3 6 80mm 80mm...
Страница 23: ...A 16 1 2 3 2...
Страница 25: ...A 18 2 4 2 K1 K2 DC24V DC24V 2 2 F39 JC A L F39 JC A D RS 485 B RS 485 A K3 K1 K2 K3 K1 1 1 1 1 1 0 V...
Страница 30: ...A 23 1 2 F3SN B 1 3 5 OFF 1 F3SN B P70 4 9 24V OFF 5 6 1 3 3 2 3 F3SN B 4...
Страница 31: ...A 24 2 2 8 1 4 1 5 6 5 6 7 3 24V 2 3 1 4 1 2 2 2 0V RS 485 B RS 485 A 7 1 24V 2 2 4 2 NO...
Страница 32: ...A 25 OFF OFF OFF ON OFF 25 s 160 200 s OFF OFF ON ON OFF 130 s ON...