Section 2 Wiring and Mounting
B-9
<Reference> Method for calculating the safety distance as provided by ANSI R15.06 (US)
(for intrusion perpendicular to the detection zone)
Safety distance (S) = Intrusion speed into the detection zone (K) x Response time (Ts + Tc + Tr)
+ Additional distance (Dpf) ...(4)
Where: K = Intrusion speed: 1,600 mm/s or more
Ts = Maximum time required for machine/equipment to stop (s)
Tr = F3SH-A response time (s) *1
Tc = Maximum time required for control system to stop(s)
Dpf = Additional distance (mm)
When the sensor is installed so that the bottom beam positioned at a height of 300mm above floor; top beam,
1200mm, Dpf = 900mm is obtained.
e.g.:
For intrusion perpendicular to the detection zone
Where: K = 1,600 mm/s, Ts + Tc = 0.06s, Tr = 0.01s, Dpf = 900mm,
From equation (4):
S = 1,600 x (0.06+0.01)+900 = 1,012mm
The sensor response time refers to the time required for output to change from ON to OFF.
Содержание F3SN-B P Series
Страница 1: ...TYPE 2 PNP Output ype F3SN B P Series Safety Light Curtain Instruction Manual ENGLISH Cat No SCEE 717...
Страница 10: ...A 3 1 2 4 b b OFF 300ms 1 b 9V Vs 2 4 1 2 5 2 1 mm...
Страница 14: ...A 7 2 1 2 1 1 F3SN B F3SN B...
Страница 17: ...A 10 2 1 3 D 0 2 3m 0 27m 3m L 2 tan10 L 0 087 m 2 1 4 F3SN B 2 F3SN B L D D L D 10 10...
Страница 18: ...A 11 0 2 3m 0 54m 3m L tan10 L 0 18 m L D D 10 10...
Страница 21: ...A 14 2 3 2 3 1 F3SN B R36 mm 52mm R 3 6 R 3 6 R 3 6 80mm 80mm...
Страница 23: ...A 16 1 2 3 2...
Страница 25: ...A 18 2 4 2 K1 K2 DC24V DC24V 2 2 F39 JC A L F39 JC A D RS 485 B RS 485 A K3 K1 K2 K3 K1 1 1 1 1 1 0 V...
Страница 30: ...A 23 1 2 F3SN B 1 3 5 OFF 1 F3SN B P70 4 9 24V OFF 5 6 1 3 3 2 3 F3SN B 4...
Страница 31: ...A 24 2 2 8 1 4 1 5 6 5 6 7 3 24V 2 3 1 4 1 2 2 2 0V RS 485 B RS 485 A 7 1 24V 2 2 4 2 NO...
Страница 32: ...A 25 OFF OFF OFF ON OFF 25 s 160 200 s OFF OFF ON ON OFF 130 s ON...