9-1 Reflective Surface Interference
9 Installation
18
Figure 9-3 Unsafe Mounting Example
Interruption is not detected because of the reflection. Reflective surface interference may also appear above and
below the sensing field.
Figure 9-4 Worst Case Alignment Example
This example shows the minimum distance from the reflective surface, d, to one side of the beam center line.
Figure 9-5 Minimum Distance from a Reflective Surface as a Function of Range
Receiver
Reflective Surface
Perimter of danger area
Reflection
Interruption
a
Sensing Field
Emitter
Emitter
Receiver
Beam Angle, a
d
Reflective Surface
Operating Range, R
a
a
Perimeter of danger area
0
100
300
500
700
900
2m
4m
6m
8m
10m
12m
14m
16m
Minimum distance
Range (m)
18m
20m
1.1m
1.3m
0.3m
d(mm)