![background image](http://html1.mh-extra.com/html/omron/f3sj-b0185p25/f3sj-b0185p25_user-manual_744127046.webp)
30
Chapter
2
Des
c
ript
io
n o
f Fun
ction
s
F3SJ-E/B
User’s Manual
System Configuration and Functions
3.
The muting sensor is blocked and the safety function of the F3SJ-B is disabled
Muting sensors A1 and B1 are turned OFF but A2 and B2 are ON, so the muting function is still
working. Safety outputs 1 and 2 are turned ON.
4.
The muting function is released
Muting sensor B2 is turned OFF, the muting function is released, and the safety function of the F3SJ-B
is enabled.
<Installation distance>
The minimum distance, D3 [m], required for muting sensors to keep the muting function enabled is :
D3 < L . . . . . Formula (3)
L [m]: Length of a workpiece
The maximum distance, d2 [m], required for muting sensors to keep the muting function enabled is :
V x T1min < d2 < V x T1max . . . . . Formula (4)
V [m/s]
: Approach speed of a workpiece
T1min [s] : Muting input time limit value (minimum). It is set as 0.1 s.
T1max [s] : Muting input time limit value (maximum). It is set as 3 s.
A1
F3SJ-B
A2
Workpiece
Hazardous zone
B1
B2
A1
B1
F3SJ-B
B2
A2
Workpiece
Hazardous zone
Содержание F3SJ-B0185P25
Страница 1: ...F3SJ E P25 F3SJ B P25 Series Safety Light Curtain User s Manual Cat No SCHG 732D...
Страница 12: ...x Introduction F3SJ E B User s Manual...
Страница 16: ...xiv Introduction F3SJ E B User s Manual...
Страница 52: ...36 Chapter 2 Description of Functions F3SJ E B User s Manual System Configuration and Functions...
Страница 104: ...88 Chapter 3 Wiring F3SJ E B User s Manual Wiring Installation...
Страница 124: ...108 Chapter 4 Wiring Examples F3SJ E B User s Manual Input Output Circuit and Applications...
Страница 130: ...114 Chapter 5 Maintenance Checklists F3SJ E B User s Manual Checklists...