F3SJ-E/B
User’s Manual
Input/Output Circuit and Applications
Connecting a F3SJ-B to a G9SB-301-D
•Thin (22.5 mm thick)
Use G9SB-301-B for auto reset with three N.O. and one N.C. contacts.
Use G9SB-200-D for manual reset with two N.O. contacts, or use G9SB-200-B for auto reset with two N.O. contacts.
For more information, visit OMRON's website at http://www.omron.com/
OUT
PLC
KM1
KM2
IN1 IN2
KM3
A1
14
24 34 42
41
33
23
13
T32
T31
T11
A2
G9SB-301-D
KM1
KM2
T12
K1
K1
K2
K1
S2
Auxiliary output
(Yellow)
External device
monitoring input (Red)
Interlock select input (White)
Reset input (Yellow)
Not used (Red)
S1
S4
Shield
Shield
a K2
Control
Circuit
a
T21
T22
K2
K2
K1
TH
SA
+24 VDC
0 V
*1
*1
*1
*1
M
*2
11
12
21
22
S3
KM1
KM2
Feedback loop
- F3SJ-B settings
- Auto reset mode
- Does not use external device monitoring function
- G9SB-301-D settings
- Manual reset mode
- Using feedback loop
- Using emergency stop switch
Communication
line (+) (Gray)
Communication
line (-) (Pink)
Receiver
Emitter
0 V (Blue)
T
est input (Black)
+24 V (Brown)
+24 V (Brown)
Safety output 1
(Black)
Safety output 2
(White)
0 V (Blue)
KM1,KM2 N.C. contact
PLC input 1 *
Unblocked
Blocked
External test switch
(S1)
Interlock reset switch
(S2)
Safety output
K1,K2 N.O. contact
KM1,KM2 N.O. contact
K1,K2 N.C. contact
PLC input 2
PLC output
Emergency stop switch
(S3)
* Auxiliary output gives inverted signal of
safety output.
*1 The G9SB-200-D (17.5 mm thick), with no 33-34 and 41-42, is also available.
*2 If an emergency stop switch is not used, connect safety output 1 to T12
terminal and safety output 2 to T22 directly.
S1 : External test switch (connect to 0V if a switch is not required)
S2 : Interlock reset switch
S3 : Emergency stop switch (force-opening contact)
(A165E, A22E)
S4 : Lockout reset switch (connect to 24V if a switch is not required)
KM1,KM2 : Safety relay with force-guided contact (G7SA)
or magnetic contactor
KM3 : Solid state contactor (G3J)
M : 3-phase motor
PLC : Programmable controller
(Used for monitoring -- not related to safety system)
F39-JD
A-L
F39-JD
A-D
Power
supply
+24 V
Содержание F3SJ-B0185P25
Страница 1: ...F3SJ E P25 F3SJ B P25 Series Safety Light Curtain User s Manual Cat No SCHG 732D...
Страница 12: ...x Introduction F3SJ E B User s Manual...
Страница 16: ...xiv Introduction F3SJ E B User s Manual...
Страница 52: ...36 Chapter 2 Description of Functions F3SJ E B User s Manual System Configuration and Functions...
Страница 104: ...88 Chapter 3 Wiring F3SJ E B User s Manual Wiring Installation...
Страница 124: ...108 Chapter 4 Wiring Examples F3SJ E B User s Manual Input Output Circuit and Applications...
Страница 130: ...114 Chapter 5 Maintenance Checklists F3SJ E B User s Manual Checklists...