E5L
3
External Connections
Note:
For thermistor wiring, separate the input power supply and load lines as much as possible to avoid the influence of inductive noise.
Nomenclature
Dimensions
(Unit: mm)
Thermostats
E5L-A
@
E5L-C
@
*
Control output Heating load: Terminals 8 and 12
Cooling load: Terminals 4 and 12
Be careful of the cooling load contacts, because they will be electrically
charged even when the E5L input power supply is OFF.
*
Control outputs: Terminals 8 and 12
Use the keys on the front panel to set direct/reverse operation.
250 VAC, 10 A
Control output
*
Input power supply: 100 to 240 VAC
Element-
interchangeable
Thermistor
250 VAC, 10 A
Control output
*
Input power supply: 100 to 240 VAC
Element-
interchangeable
Thermistor
Hysteresis
adjuster (DIFF.)
Operation indicator
Temperature dial
Operation Indicator
Operation
indicator
Output status
Heating load
Cooling load
Lit red.
ON
OFF
Not lit.
OFF
ON
E5L-A
@
Mode Key
Down Key
Up Key
Operation indicator
Set value indicator
Protection indicator
Process value
and set value
display
Operation Indicator: ON
Set Value Indicator: SV
Lit when the set value is displayed.
Setting Protection Indicator:
Lit when setting protection is set.
Operation
indicator
Output status
Reverse
operation
Direct operation
Lit
ON
ON
Not lit
OFF
OFF
E5L-C
@
6.4
64
75.0
(4.6)
45
35
E5L-A
@
6.4
64
70.4
45
35
E5L-C
@