manualshive.com logo in svg
background image

E5CSL/E5CWL

11

Warranty and Application Considerations

Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you 
have any questions or comments.

Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or 
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER 
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET 
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, 
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON 
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE 
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, 
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE 
MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of 
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will 
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT 
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON 
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR 
SYSTEM.

Disclaimers

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a 
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application 
requirements. Actual performance is subject to the OMRON 

Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with 
your OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

Содержание E5CSL

Страница 1: ...At the end of this document you will find links to products related to this catalog You can go directly to our shop by clicking HERE HERE ...

Страница 2: ... VDC 21 mA 2 Sensor type TC Thermocouple K J T R or S P Platinum resistance thermometer Pt100 Models with Dual Display 1 Control Output R Relay output 250 VAC 3 A Q Voltage output for driving SSR 12 VDC 21 mA 2 Alarm E5CWL only 1 Relay output 250 VAC 1 A resistive load 3 Sensor type TC Thermocouple K J T R or S P Platinum resistance thermometer Pt100 48 48 mm E5CSL 48 48 mm E5CWL Sensor Inputs The...

Страница 3: ...E53 COV19 Model E53 COV20 Model Y92F 45 Power supply voltage 100 to 240 VAC 50 60 Hz Operating voltage range 85 to 110 of rated supply voltage Power con sumption E5CSL 3 5 VA E5CWL 3 5 VA Sensor input Models with thermocouple inputs Thermocouple K J T R or S Models with platinum resistance thermometer inputs Platinum resistance thermometer Pt100 Control output Relay output SPST NO 250 VAC 3 A resi...

Страница 4: ...0 0 to 400 0 0 0 to 750 0 4 T 200 to 400 300 to 700 5 199 9 to 400 0 199 9 to 700 0 6 R 0 to 1 700 0 to 3 000 7 S 0 to 1 700 0 to 3 000 Model temperature input Set value Input type Range C F Pt input 8 Pt100 200 to 850 300 to 1500 9 199 9 to 500 0 199 9 to 900 0 Setting Alarm type Positive alarm value X Negative alarm value X 0 No alarm Output OFF 1 Deviation upper lower limit Always ON 2 Deviatio...

Страница 5: ... input type Sampling period 250 ms Affect of signal source resistance Thermocouple 0 1 C Ω max 100 Ω max See note 2 Platinum resistance thermometer 0 6 C Ω max 10 Ω max Insulation resistance 20 MΩ min at 500 VDC Dielectric strength 2 300 VAC 50 or 60 Hz for 1 min between terminals with different charge Vibration resistance Malfunction 10 to 55 Hz 20 m s2 for 10 min each in X Y and Z directions Des...

Страница 6: ...ection 2 These keys are disabled when starting and stopping operation has been disabled with operation control key protection 1 Display No 1 Displays the process value PV or parameter For the E5CSL the set point or parameter setting is also displayed 2 Display No 2 Displays the set point SP or parameter setting 3 Deviation Show the relation between the process value and the set point Indicators Li...

Страница 7: ...minal Cover E53 COV19 Note The E53 COV10 cannot be used 48 48 4 8 Front Panel E53 COV20 Note 1 This Front Panel accessory is required to attach the Y92A 48B or Y92A 48D 2 This Front Panel accessory is only the frame It does not include the plastic cover Fixture Accessory 69 6 to 77 6 87 72 72 76 4 7 67 67 Y92F 45 72 x 72 48 x 48 2 7 62 8 78 87 Panel 1to8mm Mounted to E5CWL ...

Страница 8: ...ller has 30 minutes or more to warm up after turning ON the power before starting actual control operations to ensure the correct temperature display 11 A switch or circuit breaker should be provided close to this unit The switch or circuit breaker should be within easy reach of the operator and must be marked as a disconnecting means for this unit 12 Do not use paint thinner or similar chemical t...

Страница 9: ...low Sections without any specification on their degree of protection or those with IP 0 are not waterproof Front panel IP50 Rear case IP20 Terminal section IP00 Operating Precautions 1 It takes approximately two seconds for the outputs to turn ON from after the power supply is turned ON Due consideration must be given to this time when incorporating Temperature Controllers in a sequence circuit 2 ...

Страница 10: ...E5CSL E5CWL 9 ...

Страница 11: ...E5CSL E5CWL 10 ...

Страница 12: ...ED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products Take all necessary steps to determine the suitabili...

Страница 13: ...73 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Tokyo JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tow...

Страница 14: ...ted delivery time enquiry in real time Logistics systems for the shipment of materials almost anywhere in the world Purchasing management order record and tracking of shipments To access the product click on the green button Product Code Reference Product link Timers hard plastic protective cover 48x48 156312 Y92A 48D Buy on EAN Temperature and Process Terminals cover E5CB 353953 E53 COV19 Buy on ...

Отзывы: