E5CSL/E5CWL
4
Characteristics
Note: 1.
The indication accuracy of K and T thermocouples at a temperature of
−
100
°
C max. is
±
2
°
C
±
1 digit maximum. The indication accuracy
of the R and S thermocouples at a temperature of 200
°
C max. is
±
3
°
C
±
1 digit max.
2.
R, and S sensors: 0.2
°
C/
Ω
max. (100
Ω
max.)
Electrical Life Expectancy Curve for Relays (Reference Values)
Indication accuracy
Thermocouple: (See note 1.)
(
±
0.5% of indicated value or
±
1
°
C, whichever is greater)
±
1 digit max.
Platinum resistance thermometer:
(
±
0.5% of indicated value or
±
1
°
C, whichever is greater)
±
1 digit max.
Influence of temperature
R and S thermocouple inputs:
(
±
1% of PV or
±
10
°
C, whichever is greater)
±
1 digit max.
K, J, and T thermocouple inputs:
(
±
1% of PV or
±
4
°
C, whichever is greater)
±
1 digit max.
Platinum resistance thermometer inputs:
(
±
1% of PV or
±
2
°
C, whichever is greater)
±
1 digit max.
Influence of voltage
Hysteresis
0.1 to 999.9 (in units of 0.1)
°
C/
°
F
Proportional band (P)
0.1 to 999.9 (in units of 0.1)
°
C/
°
F
Integral time (I)
0 to 3999 s (in units of 1 s)
Derivative time (D)
0 to 3999 s (in units of 1 s)
Control period
0.5, 1 to 99 s (in units of 1 s)
Alarm setting range
−
1999 to 9999 (decimal point position depends on input type)
Sampling period
250 ms
Affect of signal source resistance
Thermocouple: 0.1
°
C/
Ω
max. (100
Ω
max.) (See note 2.)
Platinum resistance thermometer: 0.6
°
C/
Ω
max. (10
Ω
max.)
Insulation resistance
20 M
Ω
min. (at 500 VDC)
Dielectric strength
2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)
Vibration resistance
Malfunction
10 to 55 Hz, 20 m/s
2
for 10 min each in X, Y, and Z directions
Destruction
10 to 55 Hz, 20 m/s
2
for 2 hrs each in X, Y, and Z directions
Shock
resistance
Malfunction
100 m/s
2
min., 3 times each in X, Y, and Z directions
Destruction
300 m/s
2
min., 3 times each in X, Y, and Z directions
Weight
Controller: Approx. 100 g, Mounting Bracket: Approx. 10 g
Degree of protection
Front panel: IP50
Rear case: IP20, Terminals: IP00
Memory protection
Non-volatile memory (number of writes: 100,000 times)
Conformed standards
EN61326, EN61010-1, IEC61010-1
VDE0106 Part 100 (Finger protection), when the terminal cover is mounted.
EMC
Emission Enclosure:
EN55011 Group1 Class A
Emission AC Mains:
EN55011 Group1 Class A
Immunity ESD:
EN61000-4-2
Immunity RF-interference:
EN61000-4-3 10 V/m
Immunity Conducted Disturbance:
EN61000-4-6 3 V
Immunity Burst:
EN61000-4-4
Immunity Surge:
EN61000-4-5
Immunity Voltage Dip/Interrupting:
EN61000-4-11
Contact current (A)
250 VAC, 30 VDC resistive load
No.
of operations (x 10
4
)
100
50
30
10
5
3
1
0
1
2
3
4
5