72
Sect
ion 3
Dev
ic
e
Net
Co
m
m
u
n
ic
at
io
n Se
tt
ings
E3X-DRT21-S
User’s Manual
Section 3
Explicit Message Communications
Note 1: A range of unit Nos. in the Instance ID should be between 0001Hex and
0010Hex.
When two-point teaching and position teaching are performed, sending a command for the second
point fails if no command for the first point is sent. Send a command for the second point after a
command for the first point is sent.
The sensor setting initialization command resets the settings of each sensor to the default.
The sensor reset command turns OFF the sensors and then turns them ON to reset the power.
Error Code List
Execute Projection
Lighting Off
With specifying a Unit No. with the Instance
ID, turns off the projection lighting by
issuing the command.
9E
Unit
Number
58
E3X, E3C
Cancel Projection
Lighting Off
With specifying a Unit No. with the Instance
ID, cancels the projection lighting that is
turned off, by issuing the command.
9E
Unit
Number
59
E3X, E3C
Reset Counter
With specifying a unit No. with the Instance
ID, resets the counter by issuing the
command.
9E
Unit
Number
5A
RM,
LDARM
Sensor
Setting Initialization
With specifying a Unit No. with the Instance
ID, resets all of the settings in the sensor to
the default settings by issuing the command.
9E
Unit
Number
45
All models
Reset
When the command is sent, all off the
connected sensors are turned OFF and
then turned ON to reset.
9E
Unit
Number
6F
All models
Explicit Messages
Functions
Command
Supported
Model
Class
ID
Instance
ID
Attribute
ID
Response Code
Error Name
Cause
08FF
Service
not supported
An error is detected in the service code.
14FF
Invalid
Attribute value
The specified Attribute value is not supported.
The written data is out of the range.
• Number of connected sensors is no within 1 to 16 or no sensors are
connected
• Number of units to be monitored for the detection level is not within 1 to 16
or no units to be monitored
16FF
Object
does not exist
The specified Instance ID is not supported.
• The unit No. specified with the Instance ID is
bigger than the number of mounted sensors.
15FF
Too much data Data is longer than the specified size.
13FF
Not enough
data
Data is shorter than the specified size.
Содержание E3X-DRT21-S
Страница 1: ...Communication Unit For Digital Type Sensor E3X DRT21 S DeviceNet User s Manual Cat No Z223 E1 03 ...
Страница 12: ...10 Introduction E3X DRT21 S User s Manual Introduction MEMO ...
Страница 16: ...14 E3X DRT21 S User s Manual Introduction Contents Introduction MEMO ...
Страница 101: ...99 E3X DRT21 S User s Manual Section 4 APPENDIX Section 4 Index MEMO ...