39
E3X-DRT21-S
User’s Manual
Sect
ion 3
Dev
ic
e
Net
Co
m
m
u
n
ic
at
io
n Se
tt
ings
Section 3
Wiring DeviceNet Communication Type
Wiring DeviceNet Communication Type
• Relationships between cable colors and signals are shown in the following table:
• Electricity power provided from the DeviceNet communication power supply are provided to the
communication unit and all of the connected sensors. Select appropriate power supply by considering
consumption electricity of the communication unit and sensors.
• Allowable current of the DeviceNet thin cable is 3 A, and that of the thick cable is 8 A. Make sure not to
exceed these limits.
• For how to calculate electricity power as the DeviceNet system, refer to "DeviceNet User's Manual"
(No. SCCC-308).
Insertion direction
White (CAN H)
Red (V+)
Black (V-)
Blue (CAN L)
Shield
Wiring direction
Color
Signal
Symbol
Black
Communication power supply, negative (-) side
V-
Blue
Signal, low side
CAN L
—
Shield
S
White
Signal, high side
CAN H
Red
Communication power supply, positive (+) side
V+