Section 3
DeviceNet Remote I/O Communications
• If the number of units to be monitored for the detection level is bigger than the number of sensors to be
communicated with, the detection level of unconnected sensors are [0000].
• When the Mobile Console is connected, data is [7FFF], because the detection level cannot be
retrieved.
• When communications with a sensor fail, the detection level of the sensor are [7FFF].
• The ON/OFF output of the sensor and update timing of the detection level are not synchronized. Note
that, even if you confirm ON/OFF state to retrieve the detection level, they are not the detection level
upon ON/OFF. Set the display settings to peak on detected and bottom on undetected to retrieve the
detection level upon ON/OFF.
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
m + 2CH
Unit No. 1 Detection level
m + 3CH
Unit No. 2 Detection level
m + 4CH
Unit No. 3 Detection level
:
:
:
:
m + nCH
Unit No. n - 1 Detection level
m + n + 1CH
Unit No. n Detection level
Number of units to be monitored for digital values: n