Explicit Message Communications
A range of unit Nos. in the Instance ID should be between 0001Hex and 0010Hex.
When a write command is executed, the setting values are written into the internal memory. How
many times the internal memory can be written is limited; if writing data in the memory one million
times or more per sensor per parameter is attempted, the internal memory might be destroyed.
When a write command is used, therefore, make sure to create a communication program that
writing times don’t exceed one million times per sensor per parameter.
Write Eco Mode
Settings
With specifying a Unit No. with the
Instance ID, writes the "Eco" mode
settings.
9C
Unit
Number
45
All models
Write Number of
Mutual Interference
Prevention Units
With specifying a Unit No. with the
Instance ID, writes the number of mutual
interference prevention units.
9C
Unit
Number
4D
EDATW,
EDARM
Explicit Messages
Functions
Command
Supported
Model
Class
ID
Instance
ID
Attribute
ID