manualshive.com logo in svg
background image

2

Standard Photoelectric Sensors

Selection Guide

Housing Material: Plastic

Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adapting the length of the cable 

(e.g. E

3

F2-R4B4-E 5M). For other cable length please contact your OMRON sales representative.

Housing material: Metal (Nickel plated brass)

Sensing method

Sensing
distance

Connection method

Order code

*

1

*

1.

Pre-wired connectors are available on request. Please contact your OMRON representative.

PNP output

NPN output

Through-beam

7 m

2  m

E

3

F2-7B4 2M

E

3

F2-7C4 2M

„

E

3

F2-7B4-P1

E

3

F2-7C4-P1

Retro-reflective with  M.S.R.

*

2

*

2.

Order reflector seperately. Models with reflector included are also available. Please contact your OMRON representative.

0.1 to 4 m 
(adjustable)

*3

*3

.

Measured with reflector E

3

9-R1S

2  m

E

3

F2-R4B4-E 2M

E

3

F2-R4C4-E 2M

„

E

3

F2-R4B4-P1-E

E

3

F2-R4C4-P1-E

Retro-reflective with M.S.R.

*

2

0.1 to 2 m

*

4

*

4.

Measured with reflector E

3

9-R1

2  m

E

3

F2-R2RB41-E 2M

E

3

F2-R2RC41-E 2M

„

E

3

F2-R2RB41-P1-E

E

3

F2-R2RC41-P1-E

Diffuse-reflective

0.1 m (fixed, 
wide-beam)

2  m

E

3

F2-DS10B4-N 2M

E

3

F2-DS10C4-N 2M

„

E

3

F2-DS10B4-P1

E

3

F2-DS10C4-P1

0.

3

(adjustable)

2  m

E

3

F2-DS

3

0B4 2M

E

3

F2-DS

3

0C4 2M

„

E

3

F2-DS

3

0B4-P1

E

3

F2-DS

3

0C4-P1

1 m 
(adjustable)

2  m

E

3

F2-D1B4 2M

E

3

F2-D1C4 2M

„

E

3

F2-D1B4-P1

E

3

F2-D1C4-P1

Diffuse-reflective

0.

3

(adjustable)

2  m

E

3

F2-DS

3

0B41 2M

E

3

F2-DS

3

0C41 2M

„

E

3

F2-DS

3

0B41-P1

E

3

F2-DS

3

0C41-P1

Diffuse reflective 
(background suppression)

0.1 m (fixed)

2  m

E

3

F2-LS10B4 2M

E

3

F2-LS10C4 2M

„

E

3

F2-LS10B4-P1

E

3

F2-LS10C4-P1

Sensing method

Sensing 
distance

Connection method

Order code

*

1

PNP output

NPN output

Through-beam

7 m

2  m

E

3

F2-7B4-M 2M

E

3

F2-7C4-M 2M

„

E

3

F2-7B4-M1-M

E

3

F2-7C4-M1-M

Retro-reflective with M.S.R.

*

2

0.1 to 4 m 
(adjustable)

*3

2  m

E

3

F2-R4B4-M-E 2M

E

3

F2-R4C4-M-E 2M

„

E

3

F2-R4B4-M1-M-E

E

3

F2-R4C4-M1-M-E

Retro-reflective with M.S.R.

*

2

0.1 to 2 m

*

4

2  m

E

3

F2-R2RB41-M-E 2M E

3

F2-R2RC41-M-E 2M

„

E

3

F2-R2RB41-M1-M-E E

3

F2-R2RC41-M1-M-E

Diffuse-reflective

0.1 m (fixed, 
wide-beam)

2  m

E

3

F2-DS10B4-M 2M

E

3

F2-DS10C4-M 2M

„

E

3

F2-DS10B4-M1-M

E

3

F2-DS10C4-M1-M

0.

3

(adjustable)

2  m

E

3

F2-DS

3

0B4-M 2M

E

3

F2-DS

3

0C4-M 2M

„

E

3

F2-DS

3

0B4-M1-M

E

3

F2-DS

3

0C4-M1-M

1 m 
(adjustable)

2  m

E

3

F2-D1B4-M 2M

E

3

F2-D1C4-M 2M

„

E

3

F2-D1B4-M1-M

E

3

F2-D1C4-M1-M

Diffuse-reflective

0.

3

(adjustable)

2  m

E

3

F2-DS

3

0B41-M 2M

E

3

F2-DS

3

0C41-M 2M

„

E

3

F2-DS

3

0B41-M1-M

E

3

F2-DS

3

0C41-M1-M

Содержание E3F2 -

Страница 1: ...l beam models High power LED to compensate for dirt and misalignment Performance and portfolio variety 1 SUS types see seperate datasheet 2 AC types see seperate datasheet 7 m 7 m 3 m Plastic Shape Se...

Страница 2: ...ed wide beam 2 m E3F2 DS10B4 N 2M E3F2 DS10C4 N 2M E3F2 DS10B4 P1 E3F2 DS10C4 P1 0 3 m adjustable 2 m E3F2 DS30B4 2M E3F2 DS30C4 2M E3F2 DS30B4 P1 E3F2 DS30C4 P1 1 m adjustable 2 m E3F2 D1B4 2M E3F2 D...

Страница 3: ...ical 1 1 Values in parentheses indicate the minimum required distance between the sensor and reflector Remark Order code Reflectors 3 m 100 mm axial types 2 m 100 mm radial types 60 x 40 mm E39 R1 4 m...

Страница 4: ...ion resistance 10 to 55 Hz 1 5 mm double amplitude for 2 hrs each direction X Y Z Shock resistance Destruction 500 m s2 each direction X Y Z Degree of protection 1 1 The IP69k test according to DIN 40...

Страница 5: ...5 3 0 0 50 100 50 100 Distance Y mm Distance X m 4 3 5 typical sensing distances E39 R1 2 4 m E39 R7 2 7 m E39 R8 3 1 m X Y Reflector 20 40 60 80 100 120 0 0 5 10 15 5 10 15 Distance Y mm Distance X m...

Страница 6: ...Gain Reflectors E39 RS3 E39 R1S E39 R40 E39 R7 E39 R8 1 2 3 4 5 0 100 10 1 0 1 Excess gain Distance X m reflector E39 R1 reflector E39 R7 reflector E39 R8 20 40 60 80 100 120 0 100 10 1 0 1 Excess ga...

Страница 7: ...g distance Background suppression Models E3F2 LS 0 2 4 6 0 50 100 150 Distance mm Spot diameter mm 20 00 10 00 0 00 10 00 20 00 40 30 20 10 0 10 20 30 40 Incline Angle Sensing Distence movement 20 00...

Страница 8: ...ase Output indicator red Output transistor Load relay Light indicator Red Main circuit 1 2 3 4 1 2 3 4 Connector Pin Arrangement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink Z...

Страница 9: ...30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink ZD VZ 36 V Stability indicator Green Only on models E3F2 R4C4 and E3F2 D1C4 Incident Interrupted ON OFF ON OFF Operate Release Output in...

Страница 10: ...0 4 E3F2 D1 4 E3F2 R4 E3F2 DS30 4 P1 E3F2 D1 4 P1 E3F2 R4 P1 4 8 dia 37 42 3 64 9 M18x1 6g Light indicator 5 4 8 16 4 dia 6 2 22 24 4 dia optical area 5 4 8 M18x1 6g Light indicator 4 7 dia 42 3 37 M1...

Страница 11: ...a 4 8 dia 4 dia 6 9 3 45 24 22 optical area 13 2 5 4 8 M18x1 6g Light indicator 4 7 dia 42 3 37 M12x1 6g 16 6 dia 73 62 6 9 optical area 24 13 2 22 3 45 37 42 3 49 3 M18x1 6g Light indicator Sensitivi...

Страница 12: ...0 4 M1 M E3F2 R4 4 M1 M E3F2 D1 4 M1 M 4 8 dia 37 42 3 64 9 Light indicator 16 4 dia 4 dia 4 M18x1 6g 24 27 7 6 2 optical area 37 42 3 Light indicator 4 8 dia 76 16 4 dia M12x1 6g 4 M18x1 6g 24 27 7 6...

Страница 13: ...dia 4 M18x1 6g 6 9 optical area 24 3 45 27 7 13 2 37 42 3 Light indicator 4 8 dia 76 16 4 dia M12x1 6g 4 M18x1 6g 65 5 6 9 24 27 7 3 45 13 2 optical area 37 42 3 49 3 64 9 Light indicator Sensitivity...

Страница 14: ...39 F31 Material reflective surface acrylic Rear surface ABS 34 40 3 52 59 9 2 7 8 1 6 7 5 7 Two 3 5 dia 4 5 84 7 4 f for M3 for M3 9 100 100 92 92 for M3 8 7 84 5 84 5 77 77 80 4 R1 70 0 6 Adhesive ta...

Страница 15: ...following locations 1 Locations subject to direct sunlight 2 Locations subject to condensation due to high humidity 3 Locations subject to corrosive gas 4 Locations where the Sensor may receive direc...

Страница 16: ...isted may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy contro...

Отзывы: