Standard Photoelectric Sensors

WARRANTY

OMRON’s exclusive warranty is that the products are free from de-
fects in materials and workmanship for a period of one year (or other
period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EX-
PRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MER-
CHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF 
THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT 
THE BUYER OR USER ALONE HAS DETERMINED THAT THE 
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF 
THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WAR-
RANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDI-
RECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR 
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE 
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, 
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the in-
dividual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRAN-
TY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS 
UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PROD-
UCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND 
MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, 
MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

SUITABILITY FOR USE

THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT 
SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR EN-
SURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED 
UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE 
FOR SUCH PURPOSES. Please refer to separate catalogs for OM-
RON's safety rated products.

OMRON shall not be responsible for conformity with any standards,
codes, or regulations that apply to the combination of products in the

customer’s application or use of the product.

At the customer’s request, OMRON will provide applicable third party
certification documents identifying ratings and limitations of use that
apply to the products. This information by itself is not sufficient for a
complete determination of the suitability of the products in combina-
tion with the end product, machine, system, or other application or
use.

The following are some examples of applications for which particular
attention must be given. This is not intended to be an exhaustive list
of all possible uses of the products, nor is it intended to imply that the
uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or

electrical interference, or conditions or uses not described in this
document.

• Nuclear energy control systems, combustion systems, railroad sys-

tems, aviation systems, medical equipment, amusement machines,
vehicles, safety equipment, and installations subject to separate in-
dustry or government regulations.

• Systems, machines, and equipment that could present a risk to life

or property.

Please know and observe all prohibitions of use applicable to the
products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING
THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PERFORMANCE DATA

Performance data given in this document is provided as a guide for
the user in determining suitability and does not constitute a warranty.
It may represent the result of OMRON’s test conditions, and the users
must correlate it to actual application requirements. Actual perfor-
mance is subject to the OMRON Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time
based on improvements and other reasons.

It is our practice to change model numbers when published ratings or
features are changed, or when significant construction changes are
made. However, some specifications of the product may be changed
without any notice. When in doubt, special model numbers may be as-
signed to fix or establish key specifications for your application on
your request. Please consult with your OMRON representative at any
time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for man-
ufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is
believed to be accurate; however, no responsibility is assumed for
clerical, typographical, or proofreading errors, or omissions.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user’s programming of a pro-
grammable product, or any consequence thereof.

In the interest of product improvement, specifications are subject to change without notice.

Cat. No. E58E-EN-01

OMRON EUROPE B.V.

Wegalaan 67-69, 
NL-21

3

2 JD, Hoofddorp,  

The Netherlands
Phone: +

3

1 2

3

 568 1

3

 00

Fax:

+

3

1 2

3

 568 1

3

 88

www.industrial.omron.eu

Содержание E3F2 -

Страница 1: ...l beam models High power LED to compensate for dirt and misalignment Performance and portfolio variety 1 SUS types see seperate datasheet 2 AC types see seperate datasheet 7 m 7 m 3 m Plastic Shape Se...

Страница 2: ...ed wide beam 2 m E3F2 DS10B4 N 2M E3F2 DS10C4 N 2M E3F2 DS10B4 P1 E3F2 DS10C4 P1 0 3 m adjustable 2 m E3F2 DS30B4 2M E3F2 DS30C4 2M E3F2 DS30B4 P1 E3F2 DS30C4 P1 1 m adjustable 2 m E3F2 D1B4 2M E3F2 D...

Страница 3: ...ical 1 1 Values in parentheses indicate the minimum required distance between the sensor and reflector Remark Order code Reflectors 3 m 100 mm axial types 2 m 100 mm radial types 60 x 40 mm E39 R1 4 m...

Страница 4: ...ion resistance 10 to 55 Hz 1 5 mm double amplitude for 2 hrs each direction X Y Z Shock resistance Destruction 500 m s2 each direction X Y Z Degree of protection 1 1 The IP69k test according to DIN 40...

Страница 5: ...5 3 0 0 50 100 50 100 Distance Y mm Distance X m 4 3 5 typical sensing distances E39 R1 2 4 m E39 R7 2 7 m E39 R8 3 1 m X Y Reflector 20 40 60 80 100 120 0 0 5 10 15 5 10 15 Distance Y mm Distance X m...

Страница 6: ...Gain Reflectors E39 RS3 E39 R1S E39 R40 E39 R7 E39 R8 1 2 3 4 5 0 100 10 1 0 1 Excess gain Distance X m reflector E39 R1 reflector E39 R7 reflector E39 R8 20 40 60 80 100 120 0 100 10 1 0 1 Excess ga...

Страница 7: ...g distance Background suppression Models E3F2 LS 0 2 4 6 0 50 100 150 Distance mm Spot diameter mm 20 00 10 00 0 00 10 00 20 00 40 30 20 10 0 10 20 30 40 Incline Angle Sensing Distence movement 20 00...

Страница 8: ...ase Output indicator red Output transistor Load relay Light indicator Red Main circuit 1 2 3 4 1 2 3 4 Connector Pin Arrangement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink Z...

Страница 9: ...30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink ZD VZ 36 V Stability indicator Green Only on models E3F2 R4C4 and E3F2 D1C4 Incident Interrupted ON OFF ON OFF Operate Release Output in...

Страница 10: ...0 4 E3F2 D1 4 E3F2 R4 E3F2 DS30 4 P1 E3F2 D1 4 P1 E3F2 R4 P1 4 8 dia 37 42 3 64 9 M18x1 6g Light indicator 5 4 8 16 4 dia 6 2 22 24 4 dia optical area 5 4 8 M18x1 6g Light indicator 4 7 dia 42 3 37 M1...

Страница 11: ...a 4 8 dia 4 dia 6 9 3 45 24 22 optical area 13 2 5 4 8 M18x1 6g Light indicator 4 7 dia 42 3 37 M12x1 6g 16 6 dia 73 62 6 9 optical area 24 13 2 22 3 45 37 42 3 49 3 M18x1 6g Light indicator Sensitivi...

Страница 12: ...0 4 M1 M E3F2 R4 4 M1 M E3F2 D1 4 M1 M 4 8 dia 37 42 3 64 9 Light indicator 16 4 dia 4 dia 4 M18x1 6g 24 27 7 6 2 optical area 37 42 3 Light indicator 4 8 dia 76 16 4 dia M12x1 6g 4 M18x1 6g 24 27 7 6...

Страница 13: ...dia 4 M18x1 6g 6 9 optical area 24 3 45 27 7 13 2 37 42 3 Light indicator 4 8 dia 76 16 4 dia M12x1 6g 4 M18x1 6g 65 5 6 9 24 27 7 3 45 13 2 optical area 37 42 3 49 3 64 9 Light indicator Sensitivity...

Страница 14: ...39 F31 Material reflective surface acrylic Rear surface ABS 34 40 3 52 59 9 2 7 8 1 6 7 5 7 Two 3 5 dia 4 5 84 7 4 f for M3 for M3 9 100 100 92 92 for M3 8 7 84 5 84 5 77 77 80 4 R1 70 0 6 Adhesive ta...

Страница 15: ...following locations 1 Locations subject to direct sunlight 2 Locations subject to condensation due to high humidity 3 Locations subject to corrosive gas 4 Locations where the Sensor may receive direc...

Страница 16: ...isted may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy contro...

Отзывы: