103
Using DeviceNet Scanner Demo
Section 5-2
Connecting to the
Network
Use the following procedure to connect the Board to the DeviceNet network
(i.e., go online).
1,2,3...
1.
Select
Online
from the Scanner menu.
2.
The following Go Online Window will be displayed.
3.
Set the Board’s node address (MAC ID) and baud rate, and click
OK
.
4.
The Board will go online, i.e., will be connected to the DeviceNet network.
The status bar will indicate the online status (“OL” at the far right) and the
node address will be displayed next to the Board number.
Note
I/O communications have not started yet, even though the Board is online.
Setting Initial Output Data
Use the following procedure to set the initial output data before starting I/O
communications.
1,2,3...
1.
Select the Slave with the output data.
2.
Select
I/O Data
from the Scanner menu.
3.
The following window will be displayed.
Содержание DeviceNet 3G8F7-DRM21-E
Страница 1: ...OPERATION MANUAL Cat No W381 E1 02 3G8F7 DRM21 E DeviceNet PCI Board ...
Страница 2: ...3G8F7 DRM21 E DeviceNet PCI Board Operation Manual Revised July 2005 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 29: ...12 Preparation for Operation Section 1 8 ...
Страница 67: ...50 PC Watchdog Timer Management Function Section 3 11 ...
Страница 115: ...98 Maintenance API Functions Section 4 7 ...
Страница 131: ...114 Remote I O Communications Characteristics Section 6 1 ...
Страница 145: ...Index 128 ...
Страница 147: ...130 Revision History ...