D6F-PH MEMS Differential pressure Sensor User’s Manual (A288)
8
Various internal registers
In case access to internal registers are needed, the target register’s address needs to be set
to the Interface Configuration Register (address:00h and 01h).
Fig. 7 Configuration overview
Table5. Interface Configuration Register Map
Configuration
Address
Function
Note
00h
Access Address 1 (Upper byte)
Upper byte of first Access Address
01h
Access Address 2 (Lower byte)
Lower byte of first Access Address
02h
Serial Control
Write / Read Access Control
03h
Write Buffer 0
Data to be written at Address
04h
Write Buffer 1
Data to be written at A 1
05h
Write Buffer 2
Data to be written at A 2
06h
Write Buffer 3
Data to be written at A 3
07h
Read Buffer 0
Data read from Address
08h
Read Buffer 1
Data read from A 1
09h
Read Buffer 2
Data read from A 2
0Ah
Read Buffer 3
Data read from A 3
0Bh
Initialize
0Dh
Power Sequence
Hardware reset control
Upper byte
:
bit[15:8] of 16bit data, Lower byte
:
bit[7:0] of 16bit data
I2C Configuration resister
HOST
Access address
Control
R/W Data
No. of bytes (Max. 4)
ROM /
Resister