D6F-PH MEMS Differential pressure Sensor User’s Manual (A288)
6. Usage
6-1. Recommended tube connection method of D6F-PH
When connecting the D6F-PH sensor in a bypass configuration, the sensor is able to
detect fine pressure changes. This is achieved by providing an orifice in the main channel,
which generates a small pressure change before and after the orifice. The D6F-PH will be
connected to the bypass flow path from the pressure port which is provided before and after
the orifice.
Fig. 5 Recommended tube connection method of D6F-PH
Here, the inner diameter of the bypass tube which is connected to the D6F-PH is 4[mm]
and its length is 800[mm] or less.
Orifice
Main Channel
Pressure Port
Flow direction
of main channel
Bypass flow path
length is 800[mm] or less
High Pressure side
Lower Pressure side