G-150
Safety Sensors / Components
Other
Make sure that the D4BS is located outside the safety door and that
no metal dust, oil, or chemical will be sprayed onto the D4BS. Other-
wise, the D4BS may soon fail to operate due to the penetration of
metal dust, oil, or chemical.
Tightening Torque
Be sure to tighten each screw of the D4BS properly, otherwise the
D4BS may malfunction.
Note: 1.
Apply a torque of 0.78 o 0.88 N·m if the D4BS is a three-con-
duit model.
2.
Apply a torque of 4.90 to 5.88 N·m in the case of an Allen-
head bolt. If it is a pan head screw, apply a torque of 2.35 to
2.75 N·m.
Mounting Dimensions (M5)
The D4BS can be mounted more securely by adding two protruding
portions, each of which is 5 mm maximum in height and
5
–0.05
/
–0.15
mm in diameter as shown below.
Operating Key Mounting Dimensions
Changes in Head Mounting Direction
By removing the screws on the four corners of the head, the head
can be reset in any of four directions. The head direction can be
changed with or without the Operation Key inserted in the head.
Make sure that no foreign materials penetrate through the head and
that the head is tightened securely within the proper torque range.
No.
Type
Torque
1
M3.5 terminal screw (including
ground terminal screw)
0.59 to 0.78 N·m
2
Cover mounting screw
(see note 1)
1.18 to 1.37 N·m
3
Head mounting screw
0.78 to 0.98 N·m
4
M5 body mounting screw
(see note 2)
4.90 to 5.88 N·m
5
Operation Key mounting screw 2.35 to 2.75 N·m
6
Connector
1.77 to 2.16 N·m
7
Cap screw
1.27 to 1.67 N·m
27
±
0.1
59.3
±
0.1
60
30
30
40
42
Mounting hole
Mounting side
Standard Model
Three-conduit Model
Protruding portions
5
-
0.05
dia. holes, max. height 5
-
0.15
-
0.15
Insertion hole for protrusions
5
-
0.05
dia. holes, max. height 5
20
±
0.1
40
±
0.1
30
±
0.1
Horizontal Mounting
Vertical Mounting
Adjustable Mounting (Horizontal)
Two, M5
Two, M5
Two, M5
F502-EN2-04.book Seite 150 Dienstag, 26. Juli 2005 5:48 17