D4B
S
G-145
D4BS
Characteristics
Note: 1.
The above values are initial values.
2.
Although the switch box is protected from dust, oil, or water penetration, do not use the D4BS in places where dust, oil, water, or chemicals
may penetrate through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
3.
The durability is for an ambient temperature of 5
°
C to 35
°
C and an ambient humidity of 40% to 70%. Contact your OMRON sales rep-
resentative for more detailed information on other operating environments.
4.
These figures are minimum requirements for safe operation.
Contact Form (Diagrams Show State with Key Inserted)
Note:
The terminal numbers are in accordance with EN50013, and the contact symbols are in accordance with IEC947-5-1.
Degree of protection (see note 2)
IP67 (EN60947-5-1)
Durability (see note 3)
Mechanical:1,000,000 operations min.
Electrical:500,000 operations min. (10 A at 250 VAC, resistive load)
Operating speed
0.1 m/s to 0.5 m/s
Operating frequency
30 operations/min max.
Rated frequency
50/60 Hz
Contact gap
2 x 2 mm min.
Direct opening force (see note 4)
19.61 N min. (EN60947-5-1)
Direct opening travel (see note 4)
20 mm min. (EN60947-5-1)
Full stroke
23 mm min.
Insulation resistance
100 M
Ω
min. (at 500 VDC) between terminals of same or different
polarity, between each terminal and ground, and between each ter-
minal and non-current-carrying metal part
Contact resistance
25 m
Ω
max. (initial value)
Rated insulation voltage (U
i
)
600 V (EN60947-5-1)
Conventional enclosed thermal current (I
the
)
20 A (EN60947-5-1)
Dielectric strength (Uimp)
Impulse dielectric strength (U
imp
) 4 kV (EN60947-5-1) between ter-
minals of same or different polarity, between current-carrying metal
parts and ground, and between each terminal and non-current-car-
rying metal part
Switching overvoltage
1,500 V max. (EN60947-5-1)
Conditional short-circuit current
100 A (EN60947-5-1)
Pollution degree (operating environment)
3 (EN60947-5-1)
Insulation class
Class I (with ground terminal)
Vibration resistance
Malfunction: 10 to 500 Hz, 0.65-mm single amplitude
Shock resistance
Destruction:1,000 m/s
2
min. (IEC68-2-27)
Malfunction:300 m/s
2
min. (IEC68-2-27)
Ambient temperature
Operating:-40°C to 80°C (with no icing)
Ambient humidity
Operating:95% max.
Weight
Approx. 285 g (in the case of D4BS-15FS)
Model
Contact form
Diagram
Remarks
D4BS-
#
5
#
S
1NC/1NO
D4BS-
#
A
#
S
2NC
11
23
24
12
Zb
11 - 12
23 - 24
Stroke
ON
Operation Key
insertion com-
pletion position
Extraction
completion
position
Only NC contact 11-12
has an approved direct
opening mechanism.
Terminals 11-12 and
23-24 can be used as
unlike poles.
11
21
12
22
Zb
11 - 12
21 - 22
Stroke
ON
Operation Key
insertion com-
pletion position
Extraction
completion
position
NC contacts 11-12 and
21-22 have an
approved direct
opening mechanism.
Terminals 11-12 and
21-22 can be used as
unlike poles.