Wiring Example
The application examples shown are suggestions. However, these do not exempt the user from carefully checking whether the safety door switch
and its set up are suitable for the individual application.
The power supply for the safety door switch must provide protection against permanent overvoltage. To that effect, stabilized PELV supply units
must be used. The safety outputs can be directly connected in the safety circuit of the control system. For applications of PL e / safety category 4
in accordance with ISO 13849-1, the safety outputs of safety door switch or safety door switch of the chain must be connected to a safety controller
or safety relay unit of the same Safety Category. Inductive loads (e.g. contactors, relays, etc.) are to be provided with suitable interference
suppression circuitry.
If the safety door switch is wired to relays or to non-safety relevant control components, a new risk analysis must be carried out.
If the safety door switch is connected to the safety input of a safety controller or safety relay unit, the controller must have a dual-channel monitoring
time of at least 100 ms and the accepted test pulse duration of at least 1 ms. Also, the cross-wire-short monitoring function must be disabled.
D41G series connection example
When connecting multiple safety door switches in series, apply 24 VDC to safety inputs X1 and X2 on the Nth unit, as shown in the figure below.
Connect safety outputs Y1 and Y2 to safety inputs X1 and X2 of the following safety door switch.
Connect safety outputs Y1 and Y2 of the first unit to the safety controller or safety relay unit.
Connect the auxiliary output to the PLC, etc.
When connecting a single safety door switch to the safety controller or safety relay unit, apply 24 VDC to safety inputs X1 and X2 in the same
manner as the Nth unit shown below, and then connect safety outputs Y1 and Y2 to the safety controller or safety relay unit.
1 3
2
5
6
8
X1
4
Y1
IN
X2
7
Y2
OUT
24V
GND
X1
Y1
IN
X2
Y2
OUT
24V
GND
X1
Y1
IN
X2
Y2
OUT
24V
GND
1 3
2
5
6
8
4
7
1 3
2
5
6
8
4
7
Nth D41G
N-1st D41G
1st D41G
Terminal block,
etc.
Safety
outputs
between switch and power supply
PLC, etc.
PLC, etc.
PLC, etc.
IN1
IN2
24 VDC
GND
Safety
Controller
PLC, etc.
PLC, etc.
PLC, etc.