D41G
20
Mounting
For fitting the safety door switch, two mounting holes for M6 screws with washers (washers included in delivery) are provided (tightening torque:
8 N·m). The safety door switch must not be used as a door stopper.
Any mounting position. The mounting position, however, must be chosen so that the ingress of dirt and soiling in the used opening is avoided. The
unused actuator opening must be sealed by means of the dust-proof cover (included in delivery).
Minimum distance between two safety door switches
as well as other systems with same frequency (125 kHz): 100 mm.
D41G-A2
Admissible mounting set-up
Inadmissible mounting set-up
Mounting play between safety door switch and actuator
Representation of installation options
Actuators D41G-A2 is available for exterior installation.
The safety door switch D41G is placed outside the hazardous area.
The minimum radius of the door is 400 mm.
Assumptions:
40 mm profile
• Distance between safety door switch and actuator unit:7.5 mm.
• Use standard hinge for 40 mm profile.
Actuator unit play
X = ± 1.5 mm
Y = ± 5.0 mm
Z = ± 1.0 mm
With
emergency exit
Switch
Without
emergency exit
Switch
Switch
Switch
Right door
Left door
Right door
Left door