46
CS1/CJ1W-PRM21 PROFIBUS Master DTM
Section 2-3
2.
Press the
Settings
button next to the PLC type selected. The PLC settings
window (see figure below) is displayed.
3.
In this window make the proper adjustments if necessary. The selections
made, must match the physical configuration of the PLC system. When
done, press the
OK
button.
4.
Select the
Network Type
to be used as connection between the PC and
the Unit. The available options may include other PLC systems or Commu-
nication Units, which are setup to act as a gateway. Refer to
CX-Server
Runtime User Manual (W391)
for details on configuring CX-Server.
Note 1)
For further explanation, only the direct connections between the
PC and the PLC on which the Unit is attached are considered.
These include ToolBus and SYSMAC WAY.
2)
Select the Settings button next to the Network Type selected, to
display the Network settings window, and select the Driver tab
(Toolbus is shown as example below).
5.
Make the necessary selections to facilitate communication between the
PC and the PLC CPU to which the PROFIBUS Master Unit is attached,
and press the
OK
button.
Testing CX-Server Setup
After making the settings, press the
OK
button to close the CX-Server inter-
face. In order to verify that the communication has been setup correctly, press
the Test button in the Device Setup tab of the DTM Configuration User Inter-
Содержание CX-PROFIBUS 1.0
Страница 1: ...OPERATION MANUAL CX PROFIBUS Ver 1 0 WS02 9094G Cat No W05E EN 01...
Страница 2: ...SYSMAC WS02 9094G CX PROFIBUS Ver 1 0 Operation Manual Produced July 5 2005...
Страница 3: ...iv...
Страница 7: ...viii TABLE OF CONTENTS Index 133 Revision History 137...
Страница 141: ......
Страница 153: ......