2-3 I/O Allocation for the Shutter Control System
2
2
24
SYSMAC CP1L Getting Started Guide
Designing
Systems
2-3 I/O Allocation for the Shutter Control System
I/O relays on CP1L are allocated to contacts as defined by following.
z
Inputs
z
Outputs
Device
Contact
Address
OPEN button
PB1
0.00
STOP button
PB2
0.01
CLOSE button
PB3
0.02
Car detection
sensor
SEN1
0.03
Light detection
sensor
SEN2
0.04
Upper limit LS
LS1
0.05
Lower limit LS
LS2
0.06
Device
Contact
Address
Escalation motor
MO1
100.00
De-escalation motor
MO2
100.01