A
A-4 CP1L Programming Examples
SYSMAC CP1L Getting Started Guide
137
Ap
pend
ix
When the PV of the high-speed counter matches target value 2 (3500), interrupt task
05 will be executed.
z
DM Area Setup
The comparison table for the CTBL (register comparison table) instruction should
be allocated to DM D600 through D606.
A-4-6 Using Servo Drivers for Positioning
Functions Used
z
Pulse Output by Built-in Output
Pulse signal outputs from the built-in output of a CPU unit can be used for
positioning and speed control of a servo motor driver with up to 2 axes.
Operation Overview
The following example is for a single-axis handling machine that is used to transfer
product.
Origin search will be executed, followed by positioning operations to points A and B.
Interrupt task
05
Reset "motor run"
Reset "motor stopped"
Reset "motor slow"
P_On
RSET
SET
RSET
100.00
100.01
W0.02
Channel
Value
Content
D600
0002
Items compared: 2
D601
0BB8
Target value 1: 3000 BCD (BB8 Hex)
D602
0000
D603
0004
Target value 1: Interrupt task No.4
D604
0DAC
Target value 2: 3500 BCD (DAC Hex)
D605
0000
D606
0005
Target value 2: Interrupt task No.5
Point B
Point A Origin