2-3-3 Data Setting Console Cables
Connecting Cable
Use the connecting cables in the table below (sold separately) to connect the
Unit to the Data Setting Console.
Model
Cable length (L)
C200H-CN225
2 m
C200H-CN425
4 m
L
17.5
10
16.1
17.3
39
Connection Precautions
1, 2, 3...
1. Tighten the lock screws after inserting the connector into the Unit.
2. Push the connector firmly into the Data Setting Console until the clips fully
lock.
3. Power is supplied through the connecting cable from the Heat/Cool Temper-
ature Control Unit. Nothing appears on the Data Setting Console display if
no power is supplied to input terminals A8 and A9 of the Heat/Cool Tempera-
ture Control Unit.
4. Install the supplied connector cover when the Data Setting Console is not in
use.
Wiring
Section 2-3