5. Inverter setting concerning LCD Operator
The example below explains MX2 parameter settings concerning LCD digital operator.
Code
Function name
Content
Setting parameter
F001
Output Frequency
setting
You could set the frequency when the
frequency instruction is done from the
operator.
Start Freq. ~ Max. Freq.
A001
Frequency source
setting
Select the frequency source.
00: Keypad Potentiometer
01: Terminal
02: Digital Operator
03: Modbus
04: Option Card
06: Pulse train input
07: EzSQ (Drive Programming)
10: Operation function result
A002
Run command
source setting
Select the run/stop command
source.
01: Terminal
02: Digital Operator
03: Modbus
04: Option Card
b031
Software lock
mode selection
This function prevents data
changes.
00: Lock(SFT)
01: Only FQ(SFT)
02: Lock
03: Only FQ
10: RUN chg mode
b037
Function code
display restriction
Parameter mode selection
displayed in the LCD digital
operator.
00: Full display
01: Function-specific display
02: User setting
03: Data comparison display
04: Basic display
05: Monitor display
b038
Initial-screen
selection
Select the start display.
000: Last modified parameter.
001
~
060: Display set
by d001
~
d060
201: F001 – Frequency Source
B166
Data R/W
selection
Restrict the data read/write by
LCD digital operator.
00: Read/Write OK
01: Protected
b087
Stop key selection
Enable/Disable the LCD Digital
operator STOP key.
00: Enabling
01: Disabling
02: Disabling only stop
b164
Automatic
return to the
initial display
10 minutes after the last key
operation, the display will return to
the initial parameter set by b038.
00: Enable
01: Disable
If it is set to 31(OPE) and the input is
turned on, the frequency instruction
and the run command source will be
set from the LCD digital operator.
31: OPE (Operator Control)
If it is set to 51(F-TM) and the input
is turned on, the frequency
instruction and the run command
source will be set to terminal mode.
51: F-TM (Force Terminal Mode)
C001
~
C007
Intelligent Input
terminal function
If it is set to 86(DISP) and the input is
turned on, it will show the display set
by parameter (b038).
86: DISP (Display limitation)