Chapter 5 - Maintenance
52
Adept Viper s1300 Robot User’s Guide, Rev B
Figure 5-6. Connecting Third New Battery
9. Remove the last old battery and connect the dummy connector cap disconnected
in Step 5. See
.
Figure 5-7. Reconnecting Dummy Connector Cap
10. Secure the battery support plate to the connector plate.
Tightening torque: 1.6 +/- 0.3 Nm
Old battery
New battery (3rd one)
New battery (2nd one)
Battery holder
Old battery
Battery holder
New battery (3rd one)
Dummy connector cap