2
Delay OFF Rocker Switch
A8GS-T
■
Reset Coil Ratings
Note: 1.
Voltage for coil should be set within operating voltage range and applied time should be within rated usage cycle.
Otherwise the performance of the coil may be deteriorated.
2.
In case of applying voltage within the range from 5.5 to 24 VDC to the coil, contact your OMRON sales representative.
Characteristics
Note:
Above specification values are initial values.
* For the testing condition in individual specification, contact your OMRON sales representative.
** Time from voltage applied to reset coil to actual contacts opening.
■
Approved Safety Standards
Note: 1.
There are no approved models of TV-8 rating for Delay OFF Function models.
Connector for Signal Switch Circuit and Coil Circuit
CT connectors produced by Tyco Electronics Corporation or XR connectors produced by JST shall be used
for connection of Signal and Coil circuit. Other connectors shall not be used.
*
@
indicates Housing color.
Rated voltage, current
Operating voltage range
Rated usage cycle
Coil resistance
(Coil temperature: 20 ± 2
°
C)
5 VDC 455 mA
4.5 to 5.5 VDC
ON: 50 to 100 ms
OFF: Min 5 sec
11
Ω
±
20%
Permissible operating
frequency
Mechanical
Switch operation: 20 times/min max, Coil operation: 7 times/min max
Electrical
7 times/min max
Insulation resistance
100 M
Ω
min (500 VDC)
Contact resistance
Power contact terminal
100 m
Ω
max (6 VDC to 8 V, 1 A Voltage drop method)
Signal contact terminal
100 m
Ω
max (6 VDC to 8 V, 0.1 A Voltage drop method)
Dielectric strength
Between terminals of the
same polarity
2,000 VAC 50/60 Hz 1 min
Between terminals of the
different polarity
2,000 VAC 50/60 Hz 1 min
Between each terminals of the
switch and terminals of coil
4,000 VAC 50/60 Hz 1 min
Between each terminals of
switch and ground
4,000 VAC 50/60 Hz 1 min
Vibration resistance *
Malfunction
10 to 55 Hz 1.5 mm double amplitude (Malfunction 1 ms max)
Shock resistance *
Malfunction
300 m/s
2
min (Malfunction 1 ms max)
Destruction
1000 m/s
2
max
Ambient operating temperature
-10 to +55
°
C (with no icing or condensation, 60 % RH max)
Ambient operating humidity
90 % RH max (+5 to 35
°
C with no icing or condensation)
Durability
Mechanical
Switch operation: 30,000 operations min, Coil operation: 10,000 operations min
Electrical
Switch operation: 10,000 operations min, Coil operation: 10,000 operations min
Contact release time **
100 ms max
Weight
A8GS-T
@@@@
K: Around 15 g
UL (UL61058-1)
Approved safety
standards ratings
TÜV (EN61058-1)
Approved safety
standards ratings
Power contact terminal
16 A 125 VAC
Power contact terminal
10(4) A 250 VAC
10 A 250 VAC
Signal contact terminal
0.2 A 5 VDC
Signal contact terminal
-
Tyco Electronics Corporation: CT connector
JST: XR Connector
Connector
Terminal
no.
Connection with
Switch
Pressure welding type
Crimping type
Housing
Contact
AWG #30-26
AWG #26-22
AWG #28-26
AWG #24
AWG #28-26
Signal
contact terminal
1
a (Switch COM)
179228-3
179609-1
179227-1
173977-3
2-179694-3
3XR-6
@
-P*
2
---
3
b (Switch NO)
Coil terminal
1
+ (Coil)
179228-2
173977-2
2-179694-2
2XR-6
@
-P*
2
- (Coil)