Delay OFF Rocker Switch
A8GS-T
3
Voltage applied
Voltage applied
Operation
Delay OFF Function
Power contacts are kept in ON status, even if button is operated to turn OFF by manual operation of button.
And Switch is turned OFF by external signal to coil embedded in switch.
(1) Signal contact terminal and Power contact terminal are turned ON by manual operation of button.
(2) Power contact terminal is kept in ON status, even if button is operated to turn OFF by manual operation.
Only Signal contact terminal is turned OFF.
(3) Power contact terminal is turned OFF when external signal is applied to coil.
Furthermore, it is able to turn OFF both signal and power contact terminals from manual ON condition at the same time by
applying voltage to coil as Remote Reset Function.
Delay OFF Function Operation
Remote Reset Function Operation
Note: 1.
Once switch is turned ON, Power contact terminal is not able to be turned OFF by manual operation.
Please apply the voltage to the coil in order to turn OFF Power switch circuit.
Switch circuit and operating condition
Button operating
condition
Signal contact terminal
Power contact terminal
Coil terminal
Button operating
condition
Signal contact terminal
Power contact terminal
Coil terminal
OFF
(1) Manual ON
(2) Manual OFF
(3) Delay OFF / Remote Reset
OFF
(1) Manual ON
(2) Manual
Power switch terminal
is returned automatically.
(3) Delay OFF
ON
OFF
OFF
ON
OFF
OFF
No voltage applied
No voltage applied
Button is
returned
automatically.
OFF
(1) Manual
(3) Remote Reset
ON
OFF
OFF
ON
OFF
OFF
No voltage applied
No voltage applied
Power
supply 1
Power
supply 2
Load1
Load2
+
3
4
-
1
2
a
b
+
3
4
-
1
2
a
b
Load1
Load2
Power
supply 1
Power
supply 2
+
3
4
-
1
2
a
b
Load1
Load2
Power
supply 1
Power
supply 2
Power
supply 1
Power
supply 2
Load1
Load2
+
3
4
-
1
2
a
b
* 5 VDC applied to coil terminal