Characteristics
Note:
The timing of contact outputs for two or more circuits is not synchronized. Confirm performance before application.
Item
Section
Enabling switch
Emergency stop switch
(A4EG-BE2R041 only)
Pushbutton
(A4EG-BM2B041 only)
Degree of protection
IP66 (A4EG-C000041), IP65 (A4EG-BE2R041, A4EG-BM2B041)
Operating section strength
Operating direction: 200 N, 1 min
Operating direction: 367 N, 1 min
Rotating direction: 0.49 N·m, 1 min
Operating direction: 50 N, 1 min
Cable pull strength
30 N, 1 min
Allowable
operating
frequency
Electrical
20 operations/minute max.
10 operations/minute max.
(set/reset for one operation)
60 operations/minute max.
Mechanical
20 operations/minute max.
10 operations/minute max.
(set/reset for one operation)
120 operations/minute max.
Electrical durability
100,000 operations min. (rated load)
100,000 operations min.
(set/reset for one operation)
(rated load)
100,000 operations min. (rated load)
Mechanical durability
OFF-ON-OFF (direct opening):
100,000 operations min.
OFF-ON: 1,000,000 operations min.
100,000 operations min.
(set/reset for one operation)
2,000,000 operations min.
Dielectric
strength
Between
terminals of the
same polarity
2,500 VAC, 50/60 Hz, 1 minute
(impulse voltage)
1,000 VAC, 50/60 Hz, 1 minute
1,000 VAC, 50/60 Hz, 1 minute
Between
terminals of the
different polarity
2,500 VAC, 50/60 Hz, 1 minute
(impulse voltage)
2,000 VAC, 50/60 Hz, 1 minute
2,000 VAC, 50/60 Hz, 1 minute
Between each
terminal and
non-current
carrying
metallic parts
2,500 VAC, 50/60 Hz, 1 minute
(impulse voltage)
2,000 VAC, 50/60 Hz, 1 minute
2,000 VAC, 50/60 Hz, 1 minute
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Vibration
resistance
Malfunction
1.5 mm double amplitude, 10 to 55 Hz
Shock
resistance
Malfunction
150 m/s
2
max.
Ambient operating
temperature
−
10 to 55
°
C (with no icing or condensation)
Ambient operating humidity
35% to 85%
Ambient storage temperature
−
25 to 65
°
C (with no icing or condensation)
Protection against electric
shock
Class II (double insulation)
Pollution degree
(operating environment)
3 (EN 60947-5-1)
Conditional short-circuit
current
100 A (EN 60947-5-1)