A4EG
4
Specifications
Standards and EC Directives
Compliance with EC Directives and International Standards
•
Low Voltage Directive
•
GS-ET-22
Certified Standards
* Certification for CSA C22.2 No. 14 by UL is indicated by the
.
Certified Standard Ratings (Enabling Switch Section)
TÜV (EN 60947-5-1)
Note:
Use a 10-A fuse type
gI
or
gG
that conforms to IEC 60269 as the short-circuit protection device.
The fuse is not built into the Switch.
UL/CSA (UL 508, CSA C22.2 No.14), CCC (GB 14048.5)
•
24 VDC, 0.3 A (inductive load)
•
125 VAC, 1 A (resistive load)
Ratings
Certifying body
Standard
File No.
TÜV Product Service
EN 60947-5-1
(certified direct opening)
Ask your OMRON
representative.
UL *
UL 508, CSA C22.2 No.14
E76675
CQC (CCC)
GB 14048.5
Pending approval
Item
Utilization category
AC-15
DC-13
Rated operating current (Ie)
0.75 A
0.55 A
Rated operating voltage (Ue)
240 V
125 V
Item
Section
Enabling switch
Emergency stop switch
(A4EG-BE2R041 only)
Pushbutton
(A4EG-BM2B041 only)
Rated insulation voltage
250 V
---
Rated ON current
2.5 A
5 A
0.1 A
Rated load
24 VDC, 0.3 A (inductive load)
125 VAC, 1 A (resistive load)
EN certification rating:
AC-15 0.75 A/240 V
DC-13 0.55 A/125 V
General rating:
125 VAC, 5 A (resistive load)
250 VAC, 3 A (resistive load)
30 VDC, 3 A (resistive load)
UL and cUL rating:
125 VAC, 5A
(inductive load, power factor: 0.75 to 0.8)
250 VAC, 3 A
(inductive load, power factor: 0.75 to 0.8)
30 VDC, 3 A (resistive load)
General rating:
125 VAC, 0.1 A (resistive load)
8 VDC, 0.1 A (resistive load)
14 VDC, 0.1 A (resistive load)
30 VDC, 0.1 A (resistive load)
Minimum applicable load
24 VDC, 4 mA
5 VDC, 1 mA