73
V400-F050/250/350
User’s Manual
Sec
tion 5
Discrete I/
O
Communication
Section 5
Communicating with PC and Programmable Controller
Discrete I/O Communication
It is possible to execute reading from the programmable controller and output reading result
(OK/NG) via discrete I/O.
For the setting method of communication mode and conditions necessary to communicate via
discrete I/O, refer to “Setting Discrete I/O Communication Conditions” (p.48).
Connecting Diagram
Cable Wiring
Cable and signal assignment on the main unit are shown below. Just wire only
necessary terminals.
STILL/LIVE MODE
TRIG
UP
CN1
Omron Corporation
CN2
EXECUTE DOWN
POWER
OK
NG
24VDC
2D code reader
V400-F050/250/350
Cable
V400-W23/W24 (NPN type)
V400-W23P/W24P (PNP type)
Recommended: OMRON
S8VS-03024
Programmable controller
CJ Series
CS Series
Power
supply
device
* The brown and blue wires must be connected to the power supply device.
2D code reader
V400-F050/250/350
Special round connector
Discrete I/O
Name
Description
Wire color
TRIG
Input signal: Reading trigger signal
Pink
RESET
Input signal: Restart
Orange
RUN
Output signal: Output while the reading screen is
displayed.
Green
OK/NG
Output signal: (OK) (reading is successful) or (NG)
(reading fails) is output.
Black
ERROR
Output signal: Output when an error occurs.
Gray
BUSY
Output signal: Output while processing is in
progress.
Yellow
Содержание 2D CODE READER
Страница 1: ...USER S MANUAL 2D Code Reader V400 F050 250 350 Cat No Z242 E1 03...
Страница 13: ...12 Introduction Contents V400 F050 250 350 User s Manual Introduction MEMO...
Страница 85: ...84 Section 6 Troubleshooting V400 F050 250 350 User s Manual Section 6 Troubleshooting MEMO...
Страница 112: ...111 V400 F050 250 350 User s Manual MEMO...