70
Sec
tion 5
RS-
232
C Communica
tion
V400-F050/250/350
User’s Manual
Section 5
Communicating with PC and Programmable Controller
LT
FT
Function 1... Checks the exposure time.
The exposure time is output with a 4-digit numerical value at 1/100 msec.
If the exposure time is set automatically, "OK AUTO" is output.
Example: When the exposure time is 5.47 msec.
OK 0547
Function 2... Adjusts the exposure time.
Enter the exposure time with a 4-digit numerical value.
To automatically set the exposure time, enter "LT AUTO".
The value specified with the LT command causes a difference of max. 0.04 msec. However, it
will not affect the reading process.
Function... Performs teaching without changing the exposure time.
The exposure time is fixed to the currently set value.
Specify the reading condition No. between 0 and 9.
If no reading condition No. is specified, the currently used bank will be
overwritten with the teaching results.
• When teaching is successful
• When teaching has failed
Input
L
T
Output
Exposure time
O K
Input
Exposure time
L
T
Output
O K
Input
Reading condition No.
F
T
Output
O K
N G
Error Code
?