![Omntec OEL8000II Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/omntec/oel8000ii/oel8000ii_owners-manual_740735045.webp)
OEL8000II
Owners Manual
3-23
3.2.2.10 TMP
SNSR
Submenu
The TMP SNSR Submenu (see Figure 3-23) is entered from Screen #4 of the MAIN
Menu. It permits you to program the dwell time (in minutes) for the optional
temperature sensor. This is an optional feature that can be used for monitoring
temperature in locations such as refrigerators and freezers.
The second line of the LCD prompts you to enter the dwell time on the third line
using the data keypad.
---Delivery Log
TANK 1
PRODUCT TYPE
:DIESEL
Start Time:
TH 01/11/07 12:00:01
Stop Time:
TH 01/11/07 12:30:54
Start T.C. Vol.:
2666.06(G)
Start Gross Vol.:
2673.27(G)
Start Water Vol.:
191.37(G)
Start Product Level:
39.56 (In)
Start Water Level:
2.83 (In)
Start Temperature:
66.47(F)
End T.C. Vol.:
3942.33(G)
End Gross Vol.:
3952.66(G)
End Water Vol.:
1777.76(G)
End Product Level:
58.50 (In)
End Water Level:
26.31 (In)
End Temperature:
66.98(F)
Delta Gross:
1279.35(G)
Delta T.C.:
1276.27 (G)
Figure 3-22b: Delivery Log
TU 02/06/07
15:24:31
*STATUS:NORMAL
Enter Temp Sensor Dwell Time In Min:
15
ENTER |EXIT
|
|
Fig. 3-23: Temperature Sensor Submenu